Cisco Catalyst 3750-X Message Manual page 105

Hide thumbs Also See for Catalyst 3750-X:
Table of Contents

Advertisement

Chapter 2
Message and Recovery Procedures
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message PM-4-EXT_VLAN_INUSE: VLAN [dec] currently in use by [chars].
Explanation
being used by another feature. [dec] is the VLAN that is being used, and [chars] is the feature that
is using it.
Recommended Action
VLAN or to request another available VLAN.
Error Message PM-4-EXT_VLAN_NOTAVAIL: VLAN [dec] not available in Port Manager.
Explanation
used as an internal VLAN by other features. [dec] is the requested VLAN.
Recommended Action
Error Message PM-4-INACTIVE: putting [chars] in inactive state because [chars].
Explanation
switch port and VLAN. The reason for this condition is specified in the error message. The first
[chars] is the interface name, and the second [chars] is the reason.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message PM-4-INT_FAILUP: [chars] failed to come up. No internal VLAN available.
Explanation
[chars] is the interface name.
Recommended Action
configuration command to free up resources.
Error Message PM-4-INT_VLAN_NOTAVAIL: Failed to allocate internal VLAN in Port
Manager.
Explanation
Recommended Action
(such as routed ports) that require internal VLAN allocation. To delete extended-range VLANs, use
the no vlan vlan-id global configuration command. To delete a routed port, use the no switchport
interface configuration command.
OL-9772-05
The port manager did not allocate the VLAN for external use because the VLAN is
Reconfigure the feature (for example, the routed port) to use another internal
The port manager did not allocate the requested VLAN. The VLAN is probably being
Configure a different VLAN on the device.
The port is inactive because the port manager could not create a virtual port for the
Copy the message exactly as it appears on the console or in the system log.
The port manager did not allocate an internal VLAN. The interface cannot be enabled.
Remove the extended-range VLAN by using the no vlan vlan-id global
The port manager did not find any available internal VLAN.
Delete some extended-range VLANs created by users, or remove some features
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
1-7.
1-7.
PM Messages
"Error
"Error
2-87

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 3560-xCatalyst 3560-eCatalyst 3750-e

Table of Contents