Cisco Catalyst 3750-X Message Manual page 55

Hide thumbs Also See for Catalyst 3750-X:
Table of Contents

Advertisement

Chapter 2
Message and Recovery Procedures
Error Message GBIC_SECURITY-4-EEPROM_SECURITY_ERR: GBIC in [chars] failed security
check.
Explanation
the GBIC is inserted.
Recommended Action
Error Message GBIC_SECURITY-4-GBIC_INTERR: Internal error occurred in setup for GBIC
interface [chars].
Explanation
the specified SFP module interface. [chars] is the interface in which the SFP module is installed.
Recommended Action
message appears again, copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message GBIC_SECURITY-6-SFP_INSERTED: Transceiver SFP [chars] module inserted
in [chars]
Explanation
module for the interface specified in the message. The first [chars] is the module and the second
[chars] is the interface.
Recommended Action
Error Message GBIC_SECURITY-6-SFP_REMOVED: Transceiver SFP [chars] module removed
from [chars]
Explanation
specified in the message. The first [chars] is the module and the second [chars] is the interface.
Recommended Action
OL-9772-05
The GBIC in the specified port has invalid EEPROM data. [chars] is the port in which
Remove the GBIC from the port.
The system could not allocate resources or had some other problem during the setup for
Reload the switch by using the reload privileged EXEC command. If the
The online insertion and removal (OIR) facility detected a newly inserted transceiver
No action is required.
The OIR facility detected the removal of a transceiver module from the interface
No action is required.
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
1-7.
GBIC_SECURITY Messages
"Error