Variable Fields; Message Severity Levels - Cisco Catalyst 3750-X Message Manual

Hide thumbs Also See for Catalyst 3750-X:
Table of Contents

Advertisement

How to Read System Messages
SEVERITY is a single-digit code from 0 to 7 that reflects the severity of the condition. The lower
the number, the more serious the situation.
Table 1-2
Severity Level
0 – emergency
1 – alert
2 – critical
3 – error
4 – warning
5 – notification
6 – informational
7 – debugging
MNEMONIC is a code that uniquely identifies the message.
Message-text is a text string describing the condition. This portion of the message sometimes
contains detailed information about the event, including terminal port numbers, network addresses,
or addresses that correspond to locations in the system memory address space. Because the
information in these variable fields changes from message to message, it is represented here by short
strings enclosed in square brackets ([ ]). A decimal number, for example, is represented as [dec].
Table 1-3
Representation
[dec]
[char]
[chars]
[enet]
[hex]
[inet]
All syslog messages generated by a Catalyst 3750-X or 3750-E switch other than the master switch
appear with (Switch-x) where Switch-x is the number of the stack member generating the message.
Syslog messages generated by the master switch appear with no hostname string.
This example shows a partial switch system message on a switch other than a Catalyst 3750-E:
00:00:46: %LINK-3-UPDOWN: Interface Port-channel1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to up
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed
state to down 2 *Mar
(10.34.195.36)
18:47:02: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
*Mar
This example shows a partial switch system message for a stack master and a stack member switch
(hostname Switch-2) in a Catalyst 3750-E switch stack:
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
1-6

Message Severity Levels

Variable Fields

Type of Information
Decimal integer
Single character
Character string
Ethernet address (for example, 0000.FEED.00C0)
Hexadecimal integer
Internet address
1 18:46:11: %SYS-5-CONFIG_I: Configured from console by vty2
1 18:48:50.483 UTC: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
Description
System is unusable.
Immediate action required.
Critical condition.
Error condition.
Warning condition.
Normal but significant condition.
Informational message only.
Message that appears during debugging only.
Chapter 1
System Message Overview