Connection Diagrams - Axis A1001 Installation Manual

Network door controller
Hide thumbs Also See for A1001:
Table of Contents

Advertisement

AXIS A1001 Network Door Controller
Power & Relay Connector
6-pin terminal block with built-in relay for:
• External devices
• Auxiliary power (DC output)
• 0 V DC (-)
Connect locks and loads to the pins according to the hardware pin chart
generated through the hardware configuration.
Function
0 V DC (-)
Relay
12 V DC
Tampering Alarm Pin Header
Two 2-pin headers for bypassing:
• Back tampering alarm (TB)
• Front tampering alarm (TF)
Function
Back tampering alarm
Front tampering
alarm

Connection Diagrams

Connect devices according to the hardware pin chart generated through the hardware
configuration. For more information about hardware configuration and the hardware pin chart, see
Configure the Hardware, on page 23.
Pin
Notes
1, 4
2–3
For connecting relay devices. Use the
hardware pin chart. See Configure the
Hardware, on page 23.
The two relay pins are galvanically
separated from the rest of the circuitry.
5
For powering auxiliary equipment.
Note: This pin can only be used as
power out.
Pin
Notes
1–2
To bypass the front and back tampering alarm
simultaneously, connect jumpers between TB 1, TB 2 and
1–2
TF 1, TF 2 respectively.
21
Specifications
0 V DC
Max current = 700 mA
Max voltage =+30 V DC
Max voltage = +12 V DC
Max load = 500 mA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents