Control Button
The control button is used for:
Resetting the product to factory default settings. See page 35.
Connecting to an AXIS Video Hosting System service or AXIS Internet Dynamic DNS
Service. For more information about these services, see the User Manual.

Specifications

Operating Conditions
The Axis product is intended for indoor use.
Classification
IEC 60721-4-3 Class 3K3,
3M3
Power Consumption
NOTICE
NOTICE
NOTICE
Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either a
rated output power limited to≤100 W or a rated output current limited to ≤5 A.
Power supply
Power over Ethernet IEEE 802.3af/802.3at Type 1 Class 3
10–30 V DC, max 26 W
Wire Area
NOTICE
NOTICE
NOTICE
Each wire shall have an area that corresponds to AWG 28–16 (CSA) or AWG 30–14 (CUL/UL).
Select cables in compliance with your local regulations.
AWG
28–16
30–14
AXIS A1001 Network Door Controller
Temperature
0 °C to 50 °C
(32 °F to 122 °F)
Diameter mm (in)
0.321–1.29 (0.0126–0.0508)
0.255–1.63 (0.01–0.0641)
Humidity
20–85% RH (non-condensing)
Maximum load on outputs
7.5 W
14 W
16
2
Area mm
0.0810–1.31
0.0509–2.08