3–28
"A" Group: Standard Functions
Accel/Decel
Standard acceleration and deceleration is
linear. The inverter CPU can also calculate
an S-curve acceleration or deceleration
curve as shown. This profile is useful for
favoring the load characteristics in particu-
lar applications.
Curve settings for acceleration and decel-
eration are independently selected. To
enable the S-curve, use function A097
(acceleration) and A098 (deceleration).
Func.
Code
SRW Display
A097 Acceleration curve
selection
ACC LINE
A098 Deceleration curve
selection
DEC LINE
"A" Function
Name /
Set the characteristic curve of
Acc1 and Acc2, two options:
00... linear
L
01... S-curve
Set the characteristic curve of
Acc1 and Acc2, two options:
00... linear
L
01... S-curve
Output
frequency
Target
freq.
0
Acceleration period
Run
Mode
Edit
Description
Lo Hi
✘ ✘
✘ ✘
Accel. curve selection
Linear
A097 = 00
S-curve
A097 = 01
Defaults
–FE(F)
–FU
Units
(EU)
(USA)
00
00
00
00
t