Hitachi L2002 Instruction Manual page 107

L2002 series
Hide thumbs Also See for L2002:
Table of Contents

Advertisement

"A" Function
Func.
Name /
Code
SRW Display
A095 Acc1 to Acc2 frequency
transition point
ACC CHfr0000.0Hz
A295 Acc1 to Acc2 frequency
transition point, 2nd
motor
2ACCCHfr0000.0Hz
A096 Dec1 to Dec2 frequency
transition point
DEC CHfr0000.0Hz
A296 Dec1 to Dec2 frequency
transition point, 2nd
motor
2DECCHfr0000.0Hz
NOTE: For A095 and A096 (and for 2nd motor settings), if you set a very rapid Acc1 or
Dec1 time (less than 1.0 second), the inverter may not be able to change rates to Acc2 or
Dec2 before reaching the target frequency. In that case, the inverter decreases the rate of
Acc1 or Dec1 in order to achieve the second ramp to the target frequency.
Description
Output frequency at which
Accel1 switches to Accel2,
range is 0.0 to 400.0 Hz
Output frequency at which
Accel1 switches to Accel2,
range is 0.0 to 400.0 Hz
Output frequency at which
Decel1 switches to Decel2,
range is 0.0 to 400.0 Hz
Output frequency at which
Decel1 switches to Decel2,
range is 0.0 to 400.0 Hz
L200
Inverter
2
Run
Defaults
Mode
–FE(F)
–FU
Edit
(EU)
(USA)
Lo Hi
✘ ✘
0.0
0.0
✘ ✘
0.0
0.0
✘ ✘
0.0
0.0
✘ ✘
0.0
0.0
3–27
Units
Hz
Hz
Hz
Hz

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents