Item
L200
inverters,
EU types
2
400V models
USA type
Applicable motor size *2
Rated capacity (460V) kVA
Rated input voltage *6
Integrated EMC
HFEF type
filter
HFE, HFU types
Rated input current (A)
Rated output voltage *3
Rated output current (A)
Efficiency at 100% rated output (%)
Watt loss,
at 70% output
approximate (W)
at 100% output
Starting torque *7
Braking
Dynamic
braking, approx.
% torque (short
time stop from
50 / 60 Hz) *8
DC braking
Weight
HFEF type
HFE type
HFU type
400V Class Specifications, continued
030HFEF2
040HFEF2
030HFE2
040HFU2
kW
3.0
HP
4
6.2
3-phase: 380 to 480V ±10%, 50/60 Hz ±5%
Three phase filter, Category C3
10.0
3-phase: 380 to 480V (proportional to input voltage)
7.8
95.7
90
130
Capacitive feedback type, dynamic braking unit and braking
resistor optional, individually installed
Variable operating frequency, time, and braking force
kg
1.9
lb
4.19
kg
1.8
lb
3.97
kg
lb
L200
055HFEF2
040HFE2
055HFE2
055HFU2
4.0
5.5
5
7.5
6.6
10.3
11.0
16.5
8.6
13
95.9
96.6
95
135
150
187
100% at 6Hz
20%: ≤ 60Hz
1.9
5.5
4.19
12.13
1.8
3.5
3.97
7.72
1.8
5.4
3.97
11.91
1–9
Inverter
2
075HFEF2
075HFE2
075HFU2
7.5
10
12.7
20.0
16
97.0
165
227
5.7
12.57
5.6
12.35
5.6
12.35

Hide quick links: