P" Group: Expansion Card Functions - Hitachi L2002 Instruction Manual

L2002 series
Hide thumbs Also See for L2002:
Table of Contents

Advertisement

3–64

"P" Group: Expansion Card Functions

"P" Group: Expansion Card Functions
The (optional) expansion card for the L200
The following table defines the functions and their value ranges. Please refer to the
expansion card manual for more details.
NOTE: The "P" Group parameters do not appear in the parameter list shown on the
keypad display unless the expansion card is installed on the inverter.
Func.
Code
SRW Display
P044 Network comm
watchdog timer
TIMER
P045 Inverter action on
network comm error
T-OUT
P046 Polled I/O output
instance number
O-AS-INS
P047 Polled I/O input
instance number
O-AS-INS
P048 Inverter action on
network idle mode
IDLE
P049 Network motor poles
setting for RPM
P
"P" Function
Name /
Range is 0.00 to 99.99
01.00s
Five options:
00... Trip (Error Code E70)
01... Decelerate to stop and trip
FTP
(Error Code E70)
02... Hold last speed
03... Free run stop
04... Decelerate and stop
Three settings:
20, 21, 100
021
Three settings:
70, 71, 101
071
Five options:
00... Trip (Error Code E70)
01... Decelerate to stop and trip
FTP
(Error Code E70)
02... Hold last speed
03... Free run stop
04... Decelerate and stop
Range is 00 to 38 (even
numbers only)
00P
inverter has assiciated configuration data.
2
Run
Mode
Edit
Description
Lo Hi
✘ ✘
✘ ✘
✘ ✘
✘ ✘
✘ ✘
✘ ✘
Defaults
–FE(F)
–FU
Units
(EU)
(USA)
1.00
1.00
sec.
01
01
21
21
71
71
01
01
0
0

Hide quick links:

Advertisement

Table of Contents
loading