34
en | Hardware setup
5.10.2
Connecting the alarm output
Danger!
Electrical voltage.
Risk of electric shock and damage to the unit.
The contacts must not be used at AC line voltages.
The alarm output relays respond to input alarms and triggers. Only connect resistive loads to
the alarm output relays. To avoid overloading, always make sure the relay has the following
specifications.
Relay Specification
Model
Touch material
Rating (resistance load)
5.11
Power supply
DIVAR 3000
DC power is supplied from an AC/DC power supply unit delivered with the unit. The unit has
its own on/off switch to turn power supply off and on.
Specifications:
–
–
DIVAR 5000
Power is supplied from an AC power supply. The unit has its own on/off switch to turn power
supply off and on.
Specifications:
Power supply: AC input: 100-240 VAC; 1.7 A; 50/60 Hz
2013.11 | 1.1 | AM18-Q0669
External power supply unit:
–
AC input: 100-240 VAC; 1.7 A; 50/60 Hz
–
DC output: 12 VDC; 5 A
DIVAR power input: 12 VDC; 3.5 A
JRC-27F
Silver
Rated switch capacity
Maximum switch power
Maximum switch voltage
Maximum switch current
Operator Manual
DIVAR AN 3000 / DIVAR AN 5000
30 VDC 2 A, 125 VAC 1 A
125 VA 160 W
250 VAC, 220 VDC
1 A
Bosch Security Systems