en | Connections and settings
3.10

Connecting the ALARM I/O port

Alarm inputs and outputs are supplied via a 25-pole D-type socket. The screw terminal input/output
connection board supplied with the unit simplifies all alarm connections to the unit.
Figure 3.4 Alarm I/O port connector
3.10.1
Connecting the Inputs
Each (alarm) input line can be switched by a relay contact from devices such as pressure pads,
passive infra red detectors, smoke detectors and similar devices.
Wire them as either N/O (Normally Open) or N/C (Normally Closed). You can configure the alarm
inputs as N/O or N/C in the menu system. The default is N/O.
3.10.2
Connecting the Alarm Outputs
The eight alarm output relays respond to input alarms and triggers. You can configure the alarm
outputs as N/O or N/C in the menu system. The relays are active for the duration of the driving
event. Connect the application to the alarm output relays (resistive loads only). Do not exceed 1A
30V DC, 0.3A 125V AC on an alarm output relay's contacts. The contacts must not be used at AC line
voltages.
ALARM I/O - 25-pole D-type socket
F01U | 2.0 | 2008.12
R
1A
5A
E
2A
6A
L
3A
7A
A
4A
8A
Y
GND
1
9
IN
2
10
GND
3
11
IN
4
12
GND
5
13
IN
6
14
GND
7
15
IN
8
16
Signal name
Alarm_in_1
Alarm_in_2
Alarm_in_3
Alarm_in_4
Alarm_in_5
Alarm_in_6
Alarm_in_7
Alarm_in_8
Alarm_in_9
Alarm_in_10
13
1
25
14
Pin no.
1
2
3
4
5
6
7
8
9
10
User Manual
Digital Video Recorder
Relay 1
1A
Relay 2
2A
Relay 3
3A
Relay 7
7A
Relay 8
8A
Description
Alarm input 1
Alarm input 2
Alarm input 3
Alarm input 4
Alarm input 5
Alarm input 6
Alarm input 7
Alarm input 8
Alarm input 9
Alarm input 10
Bosch Security Systems
GND

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Divar dvr-8kDivar dvr-16lDivar dvr-16kDivar dvr-8l

Table of Contents