Option And Peripheral Devices; Option List - Mitsubishi Electric FR-A700 Manual

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Option and Peripheral Devices

Option List

By fitting the following options to the inverter, the inverter is provided with more functions.
Three plug-in options can be fitted at a time. (more than two same options and communication options can not be fitted)
Name
Vector control
Orientation/encoder
16-bit digital input
Digital output
Extension analog output
Relay output
CC-Link communication
LONWORKS communication
DeviceNet
communication
PROFIBUS-DP
Parameter unit (8 languages)
Parameter unit connection
cable
Operation panel connection
connector
Cable for encoder
Mitsubishi vector control dedicated
motor (SF-V5RU)
Heatsink protrusion attachment
Intercompatibility attachment
AC reactor
DC reactor
Line noise filter
High-duty brake resistor
BU type brake unit
Brake unit
Resistor unit
77
Type
FR-A7AP
FR-A7AX
FR-A7AY
FR-A7AR
FR-A7NC
FR-A7NL
FR-A7ND
FR-A7NP
communication
FR-PU07
FR-PU04
FR-CB20
FR-ADP
FR-V7CBL
FR-A7CN01 to 11
FR-AAT24
FR-A5AT
FR-HAL
FR-HEL
FR-BSF01
FR- BLF
FR-ABR
BU
FR-BU
FR-BR
MT-BU5
MT-BR5
Applications, Specifications, etc.
Vector control with encoder can be performed.
The main spindle can be stopped at a fixed position
(orientation) in combination with a pulse encoder.The
motor speed is sent back and the speed is maintained
constant.
⋅ This input interface sets the high frequency accuracy
of the inverter using an external BCD or binary digital
signal.
⋅ BCD code 3 digits (maximum 999)
⋅ BCD code 4 digits (maximum 9999)
⋅ Binary 12 bits (maximum FFFH)
⋅ Binary 16 bits (maximum FFFFH)
⋅ Output signals provided with the inverter as standard
are selected to output from the open collector.
⋅ This option adds 2 different signals that can be
monitored at the terminals AM0 and AM1, such as the
output frequency, output voltage and output current.
⋅ 20mADC or 10VDC meter can be connected.
⋅ Output any three output signals available with the inverter
as standard from the relay contact terminals.
⋅ This option allows the inverter to be operated or
monitored or the parameter setting to be changed
from a computer or PLC.
*For the FR-A7NC (CC-Link), the above operations can be done from the
PLC only.
Interactive parameter unit with LCD display
Cable for connection of operation panel or parameter
unit
indicates a cable length. (1m, 3m, 5m)
Connector to connect the operation panel (FR-DU07)
and connection cable
Connection cable for the inverter and encoder for
Mitsubishi vector control dedicated motor (SF-V5RU).
indicates a cable length. (1m, 3m, 5m)
The inverter heatsink section can be protruded outside
of the rear of the enclosure.
For a panel cut dimension drawing, refer to page 19.
Attachment for replacing with the A700 series using the
installation holes of the FR-A500 series.
Attachment for replacing with the FR-A700 series using
the installation holes of the FR-A100<Excellent> and
FR-A200<Excellent>
For harmonic suppression measures and improvement
of inverter input power factor
(total power factor approx. 88%)
For harmonic suppression measures and improvement
of inverter input power factor
(total power factor approx. 93%)
For line noise reduction
For improvement of braking capability of the built-in
brake of the inverter
For increasing the braking capability of the inverter (for
high-inertia load or negative load)
For increasing the braking capability of the inverter (for
high-inertia load or negative load)
Brake unit and resistor unit are used in combination
Applicable Inverter
Shared among all
models
Shared among all
models
FR-A720-1.5K to 90K
FR-A740-0.4K to 132K
According to capacities
FR-A740-11K, 15K
According to
capacities
According to
capacities
Compatible with
the 55K or less
Shared among all
models
Compatible with
the 22K or less
Compatible with
the 55K or less
Compatible with
the 55K or less
Compatible with
the 75K or more