Operation mode selection

Pr.79 Operation mode selection
Used to select the operation mode of the inverter.
Mode can be changed as desired between operation using external
signals (external operation), operation from the PU (FR-DU07/FR-
PU07/FR-PU04), combined operation of PU operation and external
operation (external/PU combined operation), and network operation
(when RS-485 terminals or a communication option is used).
Pr.79
Description
Setting
0
External/PU switchover mode (Press
(initial
value)
between the PU and external operation mode.)
External operation mode at power-on.
1
Fixed to PU operation mode
Fixed to external operation mode
2
Operation can be performed by switching between the
external and Net operation mode.
External/PU combined operation mode 1
Running frequency
PU (FR-DU07/FR-PU04/FR-
3
PU07) setting or external signal
input (multi-speed setting,
across terminals 4-5 (valid
when AU signal turns on)).
External/PU combined operation mode 2
Running frequency
4
External signal input
(terminal 2, 4, 1, JOG, multi-
speed selection, etc.)
Switchover mode
Switch among PU operation, external operation, and
6
NET operation while keeping the same operation
status.
External operation mode (PU operation interlock)
X12 signal ON
Operation mode can be switched to the PU operation
mode.
7
(output stop during external operation)
X12 signal OFF
Operation mode can not be switched to the PU
operation mode.
When setting parameters, refer to the instruction manual (applied) and understand instructions.
Pr.340 Communication startup mode selection
LED Indication
:Off
:On
External operation
mode
to switch
PU operation mode
External operation
mode
NET operation mode
Start signal
External signal input
(terminal STF, STR)
Start signal
Input from the PU (FR
- DU07/FR- PU04/FR-
PU07)
(
,
)
PU operation mode
External operation
mode
NET operation mode
PU operation mode
External operation
mode
Specify the operation mode at power on (Pr.340)
When power is switched on or when power comes back on after
instantaneous power failure, the inverter can be started up in the
network operation mode.
After the inverter has started up in the network operation mode,
parameter write and operation can be performed from a program.
Set this mode for communication operation using the inverter
RS-485 terminals or communication option.
You can set the operation mode at power on (reset) according
to the Pr.79 and Pr.340 settings.
Operation Mode
at Power on,
Pr.340
Pr.79
Power
Setting
Setting
Restoration,
Reset
0
(initial
As set in Pr.79.
value)
0
NET operation mode
1
PU operation mode
2
NET operation mode
External/PU
1, 2
3, 4
combined operation
*1
mode
6
NET operation mode
X12 (MRS)signal ON
.......NET operation
mode
7
X12(MRS)signal OFF
.......External operation
mode
0
NET operation mode
1
PU operation mode
2
NET operation mode
External/PU
10, 12
*1
3, 4
combined operation
mode
6
NET operation mode
External operation
7
mode
*1
The Pr.340 settings "2 or 12" is mainly used for communication operation
using the inverter RS-485 terminals.
When a value other than "9999" (selection of automatic restart after
instantaneous power failure) is set in Pr.57 Restart coasting time , the
inverter will resume the same operation state which was in before after
power has been restored from an instantaneous power failure.
*2
The operation mode cannot be switched directly between the PU
operation mode and network operation mode.
*3
Operation mode can be changed between the PU operation mode and
network operation mode with
and X65 signal.
Operation Mode
Switchover
Switching among the
external, PU, and NET
operation mode is enabled
*2
Fixed to PU operation
mode
Switching between the PU
and Net operation mode is
enabled
Switching to PU operation
mode is disabled
Operation mode switching
is disabled
Switching among the
external, PU, and NET
operation mode is enabled
while running.
Switching among the
external, PU, and NET
operation mode is enabled
*2
Fixed to external operation
mode (Forcibly switched to
external operation mode.)
Switching between the PU
and NET operation mode
is enabled
*3
Fixed to PU operation
mode
Fixed to NET operation
mode
Operation mode switching
is disabled
Switching between the PU
and NET operation mode
is enabled while running
*3
Fixed to external operation
mode (Forcibly switched to
external operation mode.)
key of the operation panel (FR-DU07)