Dedicated cable option

Name (type)
For dedicated motor
Cable for encoder
FR-V7CBL
Cable selection specifications
Wiring
Distance
5m or less
10m or less
15m or less
20m or less
30m or less
50m or less
100m or less

Encoder connector (Manufactured by Japan Aviation Electronics Industries) for reference

Straight Plug MS3106B20-29S
1-1/4-18UNEF-2B
18.3
1-3/16-18UNEF-2B
Inverter side
F-DPEVSB 12P
Earth (Ground) wire
60mm
Inverter FR-A7AP
PA1
PA2
PB1
PB2
PZ1
PZ2
PG
SD
Optional Encoder
Dedicated Cable
Wiring 0.2mm
FR-V7CBL5
2 parallels or more
2 parallels or more
FR-V7CBL15
4 parallels or more
4 parallels or more
FR-V7CBL30
6 parallels or more
*Available on request,
6 parallels or more
please consult us.
1-3/16-18UNEF-2A
9.5
55.6
Effective screw length
Cable Clamp MS3057-12A
23.8
10.3
1.6
Specifications, Structure, etc.
Encoder side connector
0.2mm
L
Encoder
A
M
B
N
L
C
K
S
D
J
F
H
G
MS3106B20-29S
(As viewed from wiring side)
Type
S
FR-V7CBL5
R
FR-V7CBL15
FR-V7CBL30
2mm
2
(Note) When a cable of 30m length or more is required,
consult our sales office.
Cable Specification
2
Using larger gauge cable
cables
2
0.4mm
or more
2
0.75mm
or more
2
1.25mm
or more
Angle Plug MS3108B20-29S
Positioning keyway
1-3/16-18
UNEF-2A
Effective screw length
(Note) This angle type connector is not optional. Please obtain it separately.
φ10
maximum allowable
φ19
4
MS3057-12A
MS3106B20-29S
Positioning keyway
A
B
C
P
D
T
R
E
F
G
Length L (m)
5
15
30
⋅ If connection cables are not available,
make cables according to the left table.
Cables to terminals PG and SD should
be connected in parallel or be larger in
size.
1-1/4-18UNEF-2B
18.3
φ23
60.7
77
cable diameter
(Unit: mm)
86