Mitsubishi Electric FR-A700 Manual page 96

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Dedicated motor outline dimension drawings
SF-V5RUF(H)
1K
Connector (for encoder)
MS3102A20-29P
LL
KB
Exhaust
Suction
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
SF-V5RUF(H)
11K
,
15K
Connector (for encoder)
MS3102A20-29P
LL
Exhaust
Suction
Direction of
Earth (ground) terminal (M8)
cooling fan wind
Mark for earthing (grounding)
With guard wires
Dimensions table
SF-V5RUF
SF-V5RUF1
SF-V5RUF3
SF-V5RUF4
Output
Output
Output
Output
(kW)
(kW)
(kW)
(kW)
1.5
2.2
1.5
3.7
2.2
1.5
5.5
3.7
2.2
7.5
5.5
3.7
1.5
11
7.5
5.5
2.2
15
11
7.5
3.7
18.5
22
15
11
18.5
15
5.5
30
37, 45
22, 30
18.5
7.5
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
For use under the shaft, the protection structure of the cooling fan is IP20.
2. Leave an enough clearance between the fan suction port and wall to ensure
adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the
load side.
3 The size difference of top and bottom of the shaft center height is
4 The 400V class motor has -H at the end of its type name.
99
LR
KL
Q
LG
LE
QK
Section
AA
A
B
B
W
S
For cooling fan (A, B)
Section BB
For motor (U, V, W)
A
B
U
W
G1
G2
V
,
18K
,
22K
KB
LR
Q
LG
LE
KL
QK
Section
AA
A
B
B
A
W
S
Section BB
For cooling fan (A, B, C)
Flange
Frame
Mass
Number
No.
(kg)
D
IE
KB
KD
FF165
90L
26.5
183.6
198.5
27
FF215
100L
37
207
130
213
27
FF215
112M
46
228
141
239
27
FF265
132S
65
266
156
256
27
FF265 132M
70
266
156
294
27
FF300 160M
110
318
207
318
56
FF300
160L
125
318
207
362
56
160
FF350 180M
363
230
378.5
56
185
FF350
180L
270
FF400
200L
406
255
485
90
290
0
0.5
(1500r/min series)
SF-V5RUF(H)
2K
Connector (for encoder)
MS3102A20-29P
LN LZ
Suction
A
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
For thermal protector (G1, G2)
Earthing (grounding)
terminal
SF-V5RUF(H)
30K
Connector (for encoder)
MS3102A20-29P
LN LZ
Suction
Direction of
Earth (ground) terminal (M12)
cooling fan wind
Mark for earthing (grounding)
With guard wires
For motor (U, V, W)
Earthing (grounding)
terminal
For thermal protector (G1, G2)
Motor
KL
LA
LB
LC
LE
LG
LL
LN
220
165
130j6
200
3.5
12
402
231
215
180j6
250
4
16
432
242
215
180j6
250
4
16
448
256
265
230j6
300
4
20
484
256
265
230j6
300
4
20
522
330
300
250j6
350
5
20
625
330
300
250j6
350
5
20
669
352
350
300j6
400
5
20
690
346
400
350j6
450
5
22
823.5
* Consult our sales office.
(flange type)
,
3K
,
5K
,
7K
LL
KB
LR
Q
LG
LE
KL
QK
Exhaust
Section
AA
B
B
W
S
Section BB
,
37K 45K
,
LL
LR
KB
Q
QK
LG
LE
Exhaust
Section
AA
B
B
KD
W
S
Section BB
Make sure to earth the earth terminal of the flange section
as well as the earth terminal in the terminal box.
Shaft End
LZ
LR
Q
QK
S
T
U
4
12
50
50
40
24j6
7
4
4
14.5
60
60
45
28j6
7
4
4
14.5
60
60
45
28j6
7
4
4
14.5
80
80
63
38k6
8
5
4
14.5
80
80
63
38k6
8
5
4
18.5
110
110
90
42k6
8
5
4
18.5
110
110
90
42k6
8
5
4
18.5
110
110
90
48k6
9
5.5
8
18.5
140
140
110
60m6
11
7
LN LZ
A
A
KL
LN LZ
A
A
(Unit: mm)
Terminal Screw Size
W
U,V,W A,B,(C) G1,G2
8
M6
M4
M4
8
M6
M4
M4
8
M6
M4
M4
10
M6
M4
M4
10
M6
M4
M4
12
M8
M4
M4
12
M8
M4
M4
14
M8
M4
M4
*
18
M10
M4
M4