Name
Power regeneration common
converter
Stand-alone reactor dedicated
for the FR-CV
Power regeneration converter
High power factor converter
Surge voltage suppression filter
Reactor
Sine wave filter
Capacitor
Manual controller
DC tach. follower
Three speed selector
Motorized speed setter
Ratio setter
Speed detector
Master controller
Soft starter
Deviation detector
Preamplifier
Pilot generator
Deviation sensor
Frequency setting
potentiometer
Frequency meter
Calibration resistor
Inverter setup software
(FR Configurator)
*
Rated power consumption. The power supply specifications of the FR series manual controllers and speed controllers are 200VAC 50Hz, 220V/220VAC 60Hz, and 115VAC 60Hz.
Type
Applications, Specifications, etc.
Unit which can return motor-generated braking energy
FR-CV
FR-CVL
back to the power supply in common converter system
Energy saving type high performance brake unit which
MT- RC
can regenerate the braking energy generated by the
motor to the power supply.
The high power factor converter switches the converter
FR-HC
section on/off to reshape an input current waveform into
a sine wave, greatly suppressing harmonics. (Used in
MT-HC
combination with the standard accessory.)
FR-ASF
Filter for suppressing surge voltage on motor
MT- BSL (-HC)
Reduce the motor noise during inverter driving
Use in combination with a reactor and a capacitor
MT- BSC
For independent operation. With frequency meter,
FR-AX
frequency potentiometer and start switch.
For synchronous operation (1.5VA) by external signal (0
FR-AL
to 5V, 0 to 10V DC) *
For three speed switching, among high, middle and low
FR-AT
speed operation (1.5VA) *
For remote operation. Allows operation to be controlled
FR-FK
from several places (5VA) *
For ratio operation. Allows ratios to be set to five
FR-FH
inverters. (3VA)*
For tracking operation by a pilot generator (PG) signal
FR-FP
(3VA) *
Master controller (5VA) for parallel operation of multiple
FR-FG
(maximum 35) inverters. *
For soft start and stop. Enables acceleration/
FR-FC
deceleration in parallel operation (3VA) *
For continuous speed control operation. Used in
FR-FD
combination with a deviation sensor or synchro (5VA) *
FR-FA
Used as an A/V converter or arithmetic amplifier (3VA) *
For tracking operation. 70V/35VAC 500Hz (at 2500r/
QVAH-10
min)
For continuous speed control operation (mechanical
YVGC-500W-NS
deviation detection) Output 90VAC/90°
For frequency setting. Wire-wound 2W 1kΩ type B
WA2W 1kΩ
characteristic
Dedicated frequency meter (graduated to 120Hz).
YM206NRI 1mA
Moving-coil type DC ammeter
For frequency meter calibration.
RV24YN 10kΩ
Carbon film type B characteristic
FR-SW2-SETUP-WE Supports an inverter startup to maintenance.
Applicable Inverter
Compatible with
the 55K or less
Compatible with
the 75K or more
Compatible with
the 55K or less
Compatible with
the 75K or more
Compatible with
the 400V class 55K
or less
Compatible with
the 75K or more
Shared among all
models