Enables 100%-torque continuous regeneration to support continuous regenerative operation for line control, etc.
Eliminates the need to use a brake unit with each inverter, reducing total space and total cost.
Saves energy since regeneration energy is used for the other inverters and excess energy is returned to the power supply.
FR-CV-(H)
Voltage/
Capacity
7.5K/11K
15K
22K/30K
37K/55K
FR-CV-(H)-AT
Voltage/
Capacity
7.5K/11K
15K
22K/30K
Power regeneration
Connection example
common converter
FR-CV-(H)
K
Three-phase
AC power
supply
*1. Remove the jumpers across terminals R/L1-R1/L11 and S/L2-S1/L21 of the inverter, and connect the control circuit power supply across terminals R1/L11-
S1/L21. Always keep the power input terminals R/L1, S/L2, T/L3 open. Incorrect connection will damage the inverter. Opposite polarity of terminals N/-, P/+
will damage the inverter.
*2. Do not insert an MCCB between the terminals P/+-N/- (between P/L+-P/+, between N/L--N/-).
*3. Assign the terminal for X10 signal using any of Pr. 178 to Pr. 189 (input terminal function selection).
*4. Always connect the power supply and terminals R/L11, S/L21, T/MC1. If the inverter is operated without connection, the power regeneration
common converter will be damaged.
Substantially suppresses power harmonics to realize the equivalent
capacity conversion coefficient K5=0 in the Japanese "Harmonic
suppression guideline for consumers who receive high voltage or
special high voltage".
Specifications
Type FR-HC
Applicable inverter capacity
Rated input voltage/frequency
Rated input current (A)
Rated output voltage (V)
*1. The applicable capacity to the high power factor converter is the total capacity of the inverters.
*2. The output voltage varies with the input voltage value.
High power factor
converter
Outline dimension
FR-HC-(H)
K
Voltage Capacity
7.5K
15K
200V
30K
55K
H7.5K
H15K
400V
H30K
H55K
Specifications, Structure, etc.
Voltage/
W
D
D1
H
Capacity
90
303
103
300
7.5K/11K/
15K
120
305
105
300
22K/30K
150
322
122
380
37K/55K
400
250
135
620
Voltage/
W
D
D1
H
Capacity
110
315
115
330
7.5K/11K/
15K
130
320
120
330
160
350
150
410
22K/30K
Dedicated stand-alone
reactor (FR-CVL)
MCCB
MC1
R/L11
R2/L12
S/L21
S2/L22
T/L31
T2/L32
7.5K
15K
*1
3.7K to 7.5K
7.5K to 15K
Three-phase 200V to 220V 50Hz
200V to 230V 60Hz
33
61
*2
293V to 335VDC
High power
Reactor 1 FR-
Reactor 2 FR-
factor converter
HCL01
FR-HC
W
H
D
W
H
D
W
220 300 190 160 155 100 240 230 160
250 400 190 190 205 130 260 270 170
340 550 195 220 230 170 340 320 180
480 700 250 210 260 225 430 470 360
220 300 190 160 150 100 240 220 160
250 400 190 190 195 130 260 260 170
340 550 195 220 215 140 340 310 180
480 700 250 280 255 190 400 380 285 270 450 203
(Unit mm)
W
D
D1
H
120
305
105
300
150
305
105
380
400
250
135
620
(Unit mm)
W
D
D1
H
130
320
120
330
160
350
150
410
R/L1
S/L2
*1
T/L3
R1/L11
S1/L21
FR-CV type
Power regeneration
Inverter
common converter
R2/L1
S2/L2
P/L+
P/+
*2
T2/L3
N/−
N/L−
P24
PC
R/L11
SD
SD
S/L21
*4
RDYA
T/MC1
RDYB
X10
*3
RSO
RES
SE
Has the power regeneration function as standard.
Connects multiple inverters to enable common converter system
operation.
200V
30K
55K
H7.5K
15K to 30K
30K to 55K
3.7K to 7.5K
115
215
17
(Unit: mm)
Outside box
High power factor converter
HCL02
FR-HCB
H
D
W
H
D
190 320 165
W
270 450 203
Reactor 1, Reactor 2
190 320 165
FR-CV-(H)
FR-CV-(H)-AT
H
D1
W
D1
D
W
D
U
V
IM
W
400V
H15K
H30K
H55K
7.5K to 15K
15K to 30K
30K to 55K
Three-phase 380V to 460V 50/60Hz
31
57
110
558V to 670VDC
Outside box
D
W
W
D
H
D
84