Option and Peripheral Devices

Options
By fitting the following options to the inverter, the inverter is provided with more functions.
One plug-in option can be fitted.
Name
16-bit digital input
Digital output
extension analog output
Relay output
CC-LINK
L
W
ON
ORKS
Parameter unit (Eightlanguages)
Parameter unit connection cable
Operation panel connection
connector
Intercompatibility attachment
AC reactor
DC reactor
Line noise filter
BU type brake unit
Brake unit
Resistor unit
Power regeneration common
converter
Dedicated stand-alone reactor
for the FR-CV
Power regeneration converter
High power factor converter
Surge voltage suppression filter
Reactor
Capacitor
49
Type
Applications, Specifications, etc.
⋅ This input interface sets the high frequency accuracy of the
inverter using an external BCD or binary digital signal.
BCD code 3 digits (maximum 999)
FR-A7AX
BCD code 4 digits (maximum 9999)
Binary 12 bits (maximum FFFH)
Binary 16 bits (maximum FFFFH)
⋅ This option provides the inverter with open collector outputs
selected from among the standard output signals.
⋅ This option adds two different signals that can be
FR-A7AY
monitored at the terminals FM and AM, such as the output
frequency, output voltage and output current.
⋅ 20mADC or 5VDC (10V) meter can be connected.
⋅ Output any three output signals available with the inverter
FR-A7AR
as standard from the relay contact terminals
⋅ This option allows the inverter to be operated or monitored
FR-A7NC
or the parameter setting to be changed from a computer or
PLC.
* For the FR-A7NC (CC-Link), the above operations can be done from the PLC
FR-A7NL
only.
FR-PU04
Interactive parameter unit with LCD display
Cable for connection of operation panel or parameter unit
FR-CB20
indicates a cable length. (1m, 3m, 5m)
Connector to connect the operation panel (FR-DU07) and
FR-ADP
connection cable
Attachment for replacing with the F700 series using the
FR-AAT
installation holes of the FR-F500.
Attachment for replacing with the F700 series using the
FR-A5AT
installation holes of the FR-A100<Excellent> and FR-
A200<Excellent>
For harmonic current reduction and inverter input power factor
FR-HAL
improvement (total power factor approx. 88%)
For harmonic current reduction and inverter input power factor
FR-HEL
improvement (total power factor approx. 93%)
FR- BSF01
For line noise reduction
FR- BLF
For increasing the braking capability of the inverter (for high-
BU
inertia load or negative load)
FR-BU
For increasing the braking capability of the inverter (for high-
MT-BU5
inertia load or negative load)
FR-BR
Brake unit and resistor unit are used in combination
MT-BR5
FR-CV
Unit which can return motor-generated braking energy back
to the power supply in common converter system
FR-CVL
Energy saving type high performance brake unit which can
MT-RC
regenerate the braking energy generated by the motor to the
power supply.
The high power factor converter switches the converter
FR-HC
section on/off to reshape an input current waveform into a
MT-HC
sine wave, greatly suppressing harmonics. (Used in
combination with the standard accessory.)
FR-ASF
Filter for suppressing surge voltage on motor
MT-BSL
Reduce the motor noise during inverter driving
Use in combination with a reactor and a capacitor
MT-BSC
Applicable
Inverter
Shared among all
models
Shared among all
models
According to
capacities
For 200V class
55K or less, 400V
class 75K or less
For the 55K or
less
Shared among all
models
For the 55K or
less
According to
capacities
For the 55K or
less
For the 75K or
more
According to
capacities
For 400V class
55K or less
For the 75K or
more

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents