Func-
Parameter
tion
810
Torque limit input method selection
811
Set resolution switchover
812
Torque limit level (regeneration)
813
Torque limit level (3rd quadrant)
814
Torque limit level (4th quadrant)
815
Torque limit level 2
816
Torque limit level during acceleration
817
Torque limit level during deceleration
Easy gain tuning response level
818
setting
819
Easy gain tuning selection
820
Speed control P gain 1
821
Speed control integral time 1
822
Speed setting filter 1
823
Speed detection filter 1
*6
824
Torque control P gain 1
825
Torque control integral time 1
826
Torque setting filter 1
827
Torque detection filter 1
828
Model speed control gain
830
Speed control P gain 2
831
Speed control integral time 2
832
Speed setting filter2
833
Speed detection filter 2
*6
834
Torque control P gain 2
835
Torque control integral time 2
836
Torque setting filter2
837
Torque detection filter 2
840
Torque bias selection
*6
841
Torque bias 1
*6
842
Torque bias 2
*6
843
Torque bias 3
*6
844
Torque bias filter
*6
845
Torque bias operation time
*6
846
Torque bias balance compensation
*6
847
Fall-time torque bias terminal 1 bias
*6
848
Fall-time torque bias terminal 1 gain
*6
849
Analog input off set adjustment
850
Control operation selection
853
Speed deviation time
854
Excitation ratio
858
Terminal 4 function assignment
859
Torque current
860
Second motor torque current
862
Notch filter time constant
863
Notch filter depth
864
Torque detection
865
Low speed detection
866
Torque monitoring reference
39
Name
Setting Range
0, 1
0, 1, 10, 11
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
1 to 15
0 to 2
0 to 1000%
0 to 20s
0 to 5s, 9999
0 to 0.1s
0 to 200%
0 to 500ms
0 to 5s, 9999
0 to 0.1s
0 to 1000%
0 to 1000%, 9999
0 to 20s, 9999
0 to 5s, 9999
0 to 0.1s
0 to 200%, 9999
0 to 500ms, 9999
0 to 5s, 9999
0 to 0.1s, 9999
0 to 3, 9999
600 to 1400%, 9999
600 to 1400%, 9999
600 to 1400%, 9999
0 to 5s, 9999
0 to 5s, 9999
0 to 10V, 9999
0 to 400%, 9999
0 to 400%, 9999
0 to 200%
0, 1
0 to 100s
0 to 100%
0, 1, 4, 9999
0 to 500A, 9999/
0 to 3600A, 9999
0 to 500A, 9999/
0 to 3600A, 9999
0 to 60
0, 1, 2, 3
0 to 400%
0 to 400Hz
0 to 400%
Minimum
Setting
Initial Value
Increments
1
0
1
0
0.1%
9999
0.1%
9999
0.1%
9999
0.1%
9999
0.1%
9999
0.1%
9999
1
2
1
0
1%
60%
0.001s
0.333s
0.001s
9999
0.001s
0.001s
1%
100%
0.1ms
5ms
0.001s
9999
0.001s
0s
1%
60%
1%
9999
0.001s
9999
0.001s
9999
0.001s
0.001s
1%
9999
0.1ms
9999
0.001s
9999
0.001s
9999
1
9999
1%
9999
1%
9999
1%
9999
0.001s
9999
0.01s
9999
0.1V
9999
1%
9999
1%
9999
0.1%
100%
1
0
0.1s
1s
1%
100%
1
0
0.01A/0.1A
9999
*2
*2
0.01A/0.1A
9999
*2
*2
1
0
1
0
0.1%
150%
0.01Hz
1.5Hz
0.1%
150%
Refer
Customer
to
Setting
Page
45
45
45
45
45
45
45
45
69
69
70
70
52
70
70
70
52
70
70
70
70
52
70
70
70
52
70
71
71
71
71
71
71
71
71
71
52
43
64
71
71
55
55
72
72
72
47
48