Installation - Electrolux EVYP5841A Cooking Manual

Table of Contents

Advertisement

Problem
The appliance does
not heat up.
The appliance does
not heat up.
The appliance does
not heat up.
The appliance does
not heat up.
The display shows
F111.
The lamp does not
operate.
If you cannot find a solution to the prob-
lem yourself, contact your dealer or the
service centre.
We recommend that you write the data here:
Model (MOD.)
Product number (PNC)
Serial number (S.N.)

14. INSTALLATION

WARNING!
Refer to the Safety chapters.
The built-in unit must meet the
stability requirements of DIN
68930.
The oven is designed to be connected to
230 - 240V ~ (50Hz) electricity supply.
The oven has an easily accessible termi-
nal block which is marked as follows:
Connection via
Cooker Control
Circuit
It is necessary that you install a double
pole switch between the oven and the
electricity supply (mains), with a minimum
Possible cause
The clock is not set.
The necessary settings are
not set.
The Child Lock is activated.
The fuse is released.
The CT Sensor plug is not
correctly installed into the
socket.
The lamp is defective.
Min. size Cable/
flex
2,5 mm²
Set the clock.
Check the settings.
Refer to "Activating and de-
activating the Child Lock
function".
Make sure that the fuse is
the cause of the malfunc-
tion. If the fuse releases
again and again, contact a
qualified electrician.
Put the plug of core temper-
ature sensor as far as possi-
ble into the socket.
Replace the lamp.
The necessary data for the service centre
is on the rating plate. The rating plate is
on the front frame of the appliance cavity.
.........................................
.........................................
.........................................
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
CAUTION!
This oven must be earthed!
The cable used to connect the oven to
the electrical supply must comply to the
specifications given below.
For UK use only
Cable/flex type
PVC / PVC twin
and earth
gap of 3 mm between the switch contacts
and of a type suitable for the required
ENGLISH
33
Remedy
Fuse
min: 15 A
max: 20 A

Advertisement

Table of Contents
loading

Table of Contents