Gas Connection - Waldorf GP8910GE Installation And Operation Manual

800 series gas griddle range electric oven
Hide thumbs Also See for GP8910GE:
Table of Contents

Advertisement

Gas Connection

NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON.
1.
It is essential that gas supply is correct for appliance to be installed and that adequate supply
pressure and volume are available. The following checks should be made before installation:-
a. Gas Type appliance has been supplied for is shown on
coloured stickers located above gas connection and on rating
plate. Check that this is correct for gas supply appliance is
being installed for. Gas conversion procedure is detailed in
this manual.
b. Supply Pressure required for this appliance is shown in
Specifications section of this manual. Check gas supply to
ensure adequate supply pressure exists.
c. Input Rate of this appliance is stated on Rating Plate and in
Specifications section of this manual. Input rate should be
checked against available gas supply line capacity.
Particular note should be taken if appliance is being
added to an existing installation.
NOTE: It is important that adequately sized piping runs directly to connection joint on appliance
with as few tees and elbows as possible to give maximum supply volume.
2.
Fit gas regulator supplied, into gas supply line as close to appliance as possible.
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and
LPG as per 'Gas Conversion Section' in this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and it
is NOT to be adjusted.
Regulator connections are
Connection to appliance is
(Refer to Specifications section for gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to individual appliance supply line.
3.
Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
unit is level and at correct height.
4.
Connect gas supply to appliance. A suitable jointing compound which resists breakdown action of
LPG must be used on every gas line connection, unless compression fittings are used.
5.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
6.
Check gas operating pressure is as shown in Specifications section.
NOTE: Measure operating pressure at burner
operating pressure test point outlet with
one burner operating at 'High Flame'
setting.
7.
Turn off mains gas supply and bleed gas out of
appliance gas lines.
8.
Turn On gas supply and appliance.
9.
Verify operating pressure remains correct.
3
/
" BSP female.
4
3
/
" BSP male.
4
Warning
D
O NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES
9
Installation
Rating Plate will be
located in this area
.
Burner Operating Pressure
Test Point (Outlet)
Fig 2
Fig 3

Advertisement

Table of Contents
loading

Table of Contents