Removing The Perc H700 And H800 Adapters - Dell PowerEdge RAID H700 User Manual

Poweredge raid controller (perc)
Hide thumbs Also See for PowerEdge RAID H700:
Table of Contents

Advertisement

Removing the PERC H700 and H800 Adapters

NOTE:
In the event that the SAS cable is accidentally pulled out when the
system is operational, reconnect the cable and see the online help of
your Dell OpenManage storage management application for the required recovery
steps.
NOTE:
Before beginning with the procedure, press <Ctrl><R> when the system is
booting to verify that no cache is preserved.
1 Perform a controlled reboot of the system and enter the PERC BIOS
Configuration Utility to ensure that there is no data present in cache. See
the "Cache Data Recovery" on page 37 for more details. Later, perform a
controller shutdown of the system as well as any attached storage
controllers.
2 Disconnect the system from the electrical outlet and remove the system
cover.
CAUTION:
damage due to improper cooling.
NOTE:
PCI-E slots, see the
support.dell.com/manuals.
For instructions on removing a PERC H800 adapter, go to step 3.
For instructions on removing a PERC H700 adapter, go to step 5.
3 Locate the PERC H800 adapter in the system and disconnect the
external cables from the adapter.
4 Remove any retention mechanism, such as a bracket screw, that may
be holding the PERC H800 in the system and gently lift the controller
from the system's PCI-E slot. For more information, see Figure 4-5.
46
Installing and Configuring Hardware
Running a system without the system cover installed may cause
For more information on removing peripherals installed in the system's
Hardware Owner's Manual
shipped with your system or at

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge raid h800Perc h700Perc h800

Table of Contents