Dell PowerEdge RAID H700 User Manual page 136

Poweredge raid controller (perc)
Hide thumbs Also See for PowerEdge RAID H700:
Table of Contents

Advertisement

Table 9-1. BIOS Errors and Warnings
Error Message
There are offline or
missing virtual drives
with preserved cache.
Please check the
cables and ensure that
all drives are
present.
Press any key to enter
the configuration
utility.
x Virtual Disk(s)
Offline
where x is the number of virtual
disks failed
x Virtual Disk(s)
Degraded
where x is the number of virtual
disks degraded
x Virtual Disk(s)
Partially Degraded
136
Troubleshooting
(continued)
Probable Cause
The controller preserves
the dirty cache from a
virtual disk if the disk
becomes offline or is
deleted because of missing
physical disks.
This preserved dirty cache
is called pinned cache, and
is preserved until you
import the virtual disk, or
discard the cache.
This warning is displayed
when the BIOS detects
virtual disks in the offline
state.
This message is displayed
when the BIOS detects
virtual disks in a degraded
state.
This message is displayed
when the BIOS detects a
single disk failure in a
RAID 6 or RAID 60
configuration.
Corrective Action
<Ctrl><R>
Use the
utility to import the
virtual disk or discard
the preserved cache.
For the steps used to
manage preserved
cache, see "Managing
Preserved Cache" on
page 96.
You must check to
determine why the
virtual disks failed and
correct the issue. The
BIOS does not take any
action.
Take corrective
action(s) to make the
virtual disks optimal.
The BIOS does not
take any action.
You must check why
the member disk is not
present to correct the
problem. The BIOS
does not take any
action.