Preparing for Operation and Monitoring
D Status Monitor
Item
Display
U-01
Frequency reference Hz (see
U-02
Output frequency
U-03
Output current
U-04
Output voltage
U-05
DC bus voltage
U-06
Input terminal status
p
U-07
Output terminal
p
status
U-08
Torque monitor
U-09
Error log (most
g (
recent one)
)
U-10
Software No.
U-11
Output power
U-13
Accumulated
operating time
3-6
Display
unit
Monitors the frequency reference. (Same as FREF)
note 1)
Hz (see
Monitors the output frequency. (Same as FOUT)
note 1)
A
Monitors the output current. (Same as IOUT)
V
Monitors the internal output voltage reference value of the
Inverter.
V
Monitors the DC voltage of the internal main circuit of the
Inverter.
---
Shows the ON/OFF status of inputs.
Not
used
---
Shows the ON/OFF status of outputs.
Not
used
%
Displays the torque being currently output as a percentage of
the rated motor torque. This display can only be made in
vector control mode.
---
The four most recent errors can be checked.
Error
generation
item
Note "1" means that the latest error is displayed. Press the
Increment Key to display the second latest error. A maxi-
mum of four errors can be displayed.
---
OMRON use only.
W
Monitors the output power of the Inverter. (See note 2.)
x10H
Monitor the accumulated operating time in 10-second units.
(See note 3.)
Chapter 3
Function
: ON
: OFF
Terminal S1: Multi-function input 1
Terminal S2: Multi-function input 2
Terminal S3: Multi-function input 3
Terminal S4: Multi-function input 4
Terminal S5: Multi-function input 5
Terminal S6: Multi-function input 6
Terminal S7: Multi-function input 7
: ON
: OFF
Terminal MA: Multi-function contact output
Terminal P1: Multi-function photo-coupler
output 1
Terminal P2: Multi-function photo-coupler
output 2
Error