List of Parameters
Para
Reg-
Name
me-
ister
ter
No.
No.
(Hex)
n098
0162
Overtorque
detection
level
n099
0163
Overtorque
detection
time
n100
0164
UP/DOWN
frequency
memory
n101
0165
Speed
search de-
celeration
time (See
note.)
n102
0166
Speed
search op-
erating lev-
el (See
note.)
n103
0167
Torque
compensa-
tion gain
n104
0168
Torque
compensa-
tion pri-
mary delay
time con-
stant
n105
0169
Torque
compensa-
tion core
loss
n106
016A
Rated
motor slip
Note Speed search deceleration time and speed search operating level can be set for 5.5-kW and
7.5-kW Inverters only.
Description
Used to set overtorque detection level.
Detection from output torque: Set as a percent-
age based on the rated motor torque as 100%.
Detection from output current: Set as a per-
centage based on the rated Inverter output cur-
rent as 100%.
Used to set the detection time for overtorque.
Used to store the adjusted frequency reference
with the UP/DOWN function.
0: Frequency not stored
1: Frequency stored
The frequency must be on hold for 5 s or
more.
Sets the speed search deceleration time as the
time required to go from 100% to 0% of the
maximum frequency.
This is a constant for adjusting the speed
search function. If "0.0" is set, the Inverter will
operate at the default time of 2.0 seconds.
Sets the speed search operating level as a
percentage, taking the Inverter's rated output
current as 100%.
This is a constant for adjusting the speed
search function. If the Inverter output current
falls below the set value, the speed search will
be judged as completed and acceleration will
begin again.
Used to set the gain of the torque compensa-
tion function.
* The default setting does not need any chan-
ges in normal operation.
Sets the response speed of the torque com-
pensation function.
* Normally, the default setting does not need
to be changed.
Sets the core loss of the motor in use.
* Normally, the default setting does not need
to be changed.
* This parameter is enabled in V/f control
mode only.
Used to set the rated slip value of the motor in
use.
* Used as the constant of the slip compensa-
tion function or vector control.
Chapter 10
Set-
Unit
Defa
Chan-
ting
of
ult
ges dur-
range
set-
set-
ting
ting
opera-
30 to
1%
160
No
200
0.1 to
0.1 s
0.1
No
10.0
0, 1
1
0
No
0.0 to
0.1 s
2.0
No
10.0
0 to
1 %
150
No
200
0.0 to
0.1
1.0
Yes
2.5
0.0 to
0.1 s
0.3
No
25.5
0.0 to
0.1 W
Varies
No
6,550
with
the
capac-
ity.
0.0 to
0.1
Varies
Yes
20.0
Hz
with
the
capac-
ity.
Ref-
er-
ing
ence
page
tion
6-32
6-32
6-45
5-35
5-35
6-35
6-35
6-35
6-37
10-23