Design
D Wires and Tightening Torque
Multi-function Contact Output (MA, MB, and MC)
Terminal
Tightening
screw size
torque
N S m
M3
0.5 to 0.6
Sequential Input (S1 through S7 and SC), Multi-function Photocoupler Output (P1,
P2, PC), RS-422/485 Communications (R+, R–, S+, S–) and Multi-function Analog
Output (AM or AC), and Pulse Train Input (RP)
Terminal
Tightening
screw size
torque
N S m
M2
0.22 to 0.25
Frequency Reference Input (FR, FS, and FC)
Terminal
Tightening
screw size
torque
N S m
M2
0.22 to 0.25 Single wire
D Solderless Terminals for Control Circuit Terminals
The use of solderless terminals for the control circuit terminals is recommended because solderless
terminals are easy to connect securely.
Note When using the following solderless terminal, make sure that the wire size is 0.5 mm
D Wiring Method
1. Loosen the terminal screws with a thin-slotted screwdriver.
2. Insert the wires from underneath the terminal block
3. Tighten the terminal screws firmly to a torque of 0.5 NSm.
Wire
Wire size mm
Single wire
0.5 to 1.25 (20 to 16) 0.75 (18)
Stranded wire
0.5 to 1.25 (20 to 16)
Wire
Wire size mm
Single wire
0.5 to 1.25 (20 to 16) 0.75 (18)
Stranded wire
0.5 to 0.75 (20 to 18)
Wire
Wire size
2
mm
(AWG)
0.5 to 1.25 (20
to 16)
Stranded wire
0.5 to 0.75 (20
to 18)
1.0 dia.
Model: Phoenix Contact's A1 0.5-8 WH
(Size: mm)
2.6 dia.
2
Recommended
(AWG)
wire size mm
(AWG)
2
Recommended
(AWG)
wire size mm
(AWG)
Recommended
2
wire size mm
(AWG)
0.75 (18)
Chapter 2
Cable
2
Cable with
polyethylene
polyethylene
sheath
Cable
2
Cable with
polyethylene
polyethylene
sheath
Cable
Special cable with
p y
polyethylene sheath and
y
shield for measurement
use
2
.
2-35