AMAX panel 4000 / AMAX panel 4000
EN
3.4

Prerequisites for Certification conform Installation

EN 50131-3 Grade 2, Environmental Class 2
All Communicators must be connected to a Central Monitoring Station.
Only the onboard Dialer and the Option Bus Communicators can be used for EN Alarm
Transmission.
max current for all components with a 18Ah Battery = 1500mA
(standby 12h, recharge Battery 80% in 72h)
(PCB=l00mA, IUI-AMAX Keypads=31mA, DX2010=35mA, DX3010=10mA, B426=100mA,
DX4020G=65mA, RF3227E=30mA, RFRC-OPT=30mA)
The Enclosure lock can only be used in non EN setup.
Bosch Sicherheitssysteme GmbH
System must be placed inside the monitored area on a stable surface.
Keypads must be mounted to the inner side of the monitored area.
Once the system is tested and ready to use, Enclosure Door and Accessory Enclosures
must be secured with the provided screws
To realize EN conform Alarm Indication and Transmission, one of the following options
must be used
Two supervised Warning devices (PO-1 PO-2 & PO+) and one ATS 2 Communicator
(onboard Dialer, B426, D4020 or DX4020G)
One self powered Warning Device and one ATS 2 Communicator (onboard Dialer,
B426, D4020 or DX4020G)
Two Communicators, one ATS 2 (onboard Dialer, B426, D4020 or DX4020G) and one
ATS 1 (onboard Dialer, B426, D4020 or DX4020G)
One ATS 3 Communicator (DX4020 or B426)
one 12V/7AH or one 12V/18Ah Battery must be connected to the System.
max current for all components with a 7Ah Battery = 550mA
To realize EN conform Arming procedure an indication of arm/disarm status must be
accessible from outside the monitored area (this indication can be time limited)
To realize EN conform Access to the Monitored Area, one of the following options must
be used
Opening a door (to the entry/exit route) must start the entry procedure
Indication of arm/disarm Status
Access to the monitored Area (doors not starting entry procedure) is prevented (e.g.
door strike, mechanically)
Telephone arming can only be used in non EN setup.
Accessory Modules, except input module (DX2010) can be used only inside the enclosure
(on the adapter plate).
When input module (DX2010) is used in the external enclosure (AE20) the tamper skirt
must be installed on the PCB of input module (DX2010)
The panel must be programmed with the EN settings indicated on the programming
sheet. When the panel is set without EN parameters, the EN Indication (on Label) must
be removed.
Quick Start Guide
Installation | en
9
2013.07 | 03 | F.01U.267.113