10
en | Configuration
4

Configuration

The control panel programming options are stored in a non-volatile flash memory. This
memory has all relevant configuration and user-specific data even after a total power loss.
Because the data retention time is quite long without power, reprogramming is not required
after powering up the control panel.
Programming with keypad is possible only when all of zones in the system are in disarmed
status and no alarm is activated. Installer Code is required for programming.
Notice!
It is not recommended to use other keypads or methods simultaneously to program the
system while programming with the current keypad.
4.1

Programming with Keypad

4.1.1

LCD Keypad Menu Programming

1.
2.
3.
4.
5.
6.
4.1.2

LED/Icon LCD Keypad Address Programming

1.
2.
3.
2013.07 | 03 | F.01U.267.113
Enable Text keypad and confirm that the system is in disarmed status.
Enter Installer Code + [958] and press [#] to get to [Installer Menu].
Programming: Select the menu and operate according to the menu prompt.
Down to the next menu: Press [▼]
Up to the previous menu: Press [▲]
Enter menu or confirm input: Press [#]
Back to the menu or delete a single input: Press [-]; or press and hold [-] for 3
seconds to end the input state and get back to the menu.
Operate according to the menu prompt. Select menu and enter data for specific
programming items according to the display on the keypad to complete
programming, step by step.
The data value ranges in the menu programming and address programming are the
same. For specific options and value ranges, see contents in LCD Keypad Menu
Programming, page 10.
After completing input, press [-] to get back to the previous menu. Complete all
programming input by repeating step 3 and press [-] to get back to the current main
menu level by level.
Press [-] to enter menu options. It is optional to save or not to save the programming
information.
Select [Save and Exit] and press [#] to save system programming data, exit menu
programming and reset system.
Enable LED keypad or Icon LCD keypad and make sure that the system is in disarmed
status.
Enter programming mode: Enter the Installer Code (the default is 1234) + [958] and
press [#].
Programming: Move to the required address and enter the value for each data bit (data
value).
After entering programming mode, the system directly enters the programming data
in the address 0000 (Receiver 1 telephone number or the initial digit of the IP
address), then
Quick Start Guide