en | Configuration
Automatic Test Report
0 = No report, 1 = Receiver 1, 2 = Receiver 2, 3 = Receiver 3, 4 = Receiver 4, 5 = Receiver
1,2,3 and 4, 6 = Receiver 1 (2,3 and 4 for backup), 7 = Receiver 1 (2 for backup) and receiver
3 (4 for backup)
Notice!
When the Transmission Format for Receiver in the receiver programming is set to 0 (not
used), i.e., setting the report option as sending report to a receiver, then the alarm control
panel will actually not send any report.
Automatic Test Report
Address 0129 - 0134
Test Report Time: Interval
00 = Do not use timing report , 01 - 99 = 1 - 99 hours
Report Time: Hour
00 - 23 = 0 - 23 hours, Others = Do not use real-time
report
Report Time: Minute
00 - 59 = 0 - 59 minutes, Others = Do not use real-time
report
Report Expiry Time
Address 0135 - 0137
000 = No time limit, 001 - 255 = 1 - 255 minutes
Installer Access Until Next Arming
Address 0138
0 = disabled, 1 = enabled
Force Arm When System Is In Trouble Condition
Address 0139
0 = disabled, 1 = enabled
Siren / PO 1+2 Supervision
Address 0140
0 = disabled, 1 = PO1 enabled, 2 = PO2 enabled, 3 =
PO1+2 enabled
2013.07 | 03 | F.01U.267.113
Quick Start Guide
AMAX panel 4000 / AMAX panel 4000
0128
6
EN=1/5/6/7
Address
Default
0129 - 0130
24
VDS-A
EN=1=24
0131 - 0132
99
0133 - 0134
99
Address
Default
0135 - 0137
000
VDS-A
EN=000
Address
Default
0138
0
VDS-A=1
Address
Default
139
1
VDS-A EN=0
Address
Default
0140
0
VDS-A EN=3