6.0 Getting to Know the
ICP-VR8488
The ICP-VR8488 Intruder Alarm System is made up
of a control panel and detection devices such as
magnetic/motion sensors and smoke sensors. The
user operates the ICP-VR8488 using either the
keypad or RF keyfobs.
If a detection device detects intrusion or smoke, the
status of the device changes from normal to faulted.
If a detection device faults when the ICP-VR8488 is
armed (AWAY Mode or STAY Mode), the
ICP-VR8488 sounds an alarm and sends an alarm
report by telephone to the security company, which
takes the appropriate action.

Figure 16: Keypad Display

1 – Zone Indicators
2 – Service indicator
3 – Power indicator
4 – STAY indicator
5 – AWAY indicator
Bosch Security Systems, Inc. | 12/08 | F01U089640-01

Getting to Know the ICP-VR8488

Table 1:
Keypad Indicator States
Indicator
Description
On – the ICP-VR8488 is armed in AWAY
Mode.
Off– the ICP-VR8488 is not armed in
AWAY
AWAY Mode.
On – the ICP-VR8488 is armed in STAY
Mode.
Off– the ICP-VR8488 is not armed in STAY
STAY
Mode.
On – AC MAINS supply is normal.
Flashing (with Service indicator) – AC
Power
MAINS supply failure.
On– a trouble condition exists. Contact the
security company.
Flashing (with Power indicator) – AC
Service
MAINS supply failure.
Zone
On – the zone is faulted.
Indicators
Off – normal condition.
Flashing – the zone is in alarm.
The OFF indicator lights when the system is
disarmed and flashes when a zone
becomes unsealed when disarmed. The
indicator stops flashing when all zones are
sealed.
The ON indicator lights when the system is
armed and flashes when an alarm occurs.
The indicator is reset after a valid User
Code is entered.
During installation the security company can
configure various zones on the ICP-VR8488 to
behave differently. Examples of different zones are
listed in the following sections.
6.1

Burglary Zones

A burglary zone sounds an alarm when faulted only
if the ICP-VR8488 is turned on (armed) in AWAY
Mode or STAY Mode. When the ICP-VR8488 is
turned off (disarmed), a burglary zone does not
sound an alarm if faulted.
6.2

24-Hour Zones

A 24-hour zone (a tamper switch, for example)
sounds an alarm when faulted whether the
ICP-VR8488 is turned on or off.
6.3

Fire Zones

A fire zone (a smoke detector, for example), sounds
an alarm when faulted whether the ICP-VR8488 is
turned on or off.
6.4

AWAY Indicator

The AWAY indicator lights when the
ICP-VR8488 is turned on in AWAY
Mode.