Rf Receiver Interface Connections; Wiring And Power Up; Figure 11: Connecting The Ac Plug Pack; Operation - Bosch ICP-VR8488 Quick Referenc Manual

Intruder alarm system
Hide thumbs Also See for ICP-VR8488:
Table of Contents

Advertisement

ICP-VR8488 | Quick Reference Guide | 4.0
Figure 11:
Connecting the AC Plug Pack
2
1 – AC power connections
2 – AC plug pack leads
17. Insert the 12 VDC 2 A battery (refer to Figure 12
on page 9).
Figure 12:
Installing the Battery
1 – Battery stand-off supports
18. Connect the keypad data cable to the keypad
connector (Figure 2 on page 6).
19. Connect the red and black battery leads from the
ICP-VR8488 PCB to the + and — terminals,
respectively, on the battery.
20. Install the cover on the ICP-VR8488.
21. Connect power to the ICP-VR8488 using the AC
plug pack (TF008).
22. Enter the factory default code (2580) for User 1
and press [#] to reset any alarm that might occur
upon system power up.
User 1 is set by factory default as a Master
Code (2580).
Bosch Security Systems, Inc. | 12/08 | F01U089640-01

RF Receiver Interface Connections

4.0 RF Receiver Interface
Connections
Figure 13:
1
1 – ICP-CC488 Control Panel
2 – RF Receiver (RF 3213/E)
4.1

Wiring and Power Up

1. Remove power from the control panel.
1
2. Connect the RF Receiver to the control panel as
shown in Figure 13 on page 9 using 0.8mm (22-
gauge) or larger wire. Wire length should not
exceed 300 m (1000 ft).
3. Apply power to the control panel. The red LED
at the center of the module turns.
4.2

Operation

The following describes the status of the module
based on the LED condition.
LED On – Module is functioning normally.
LED Off – Power failure occurred or module is not
connected correctly.
LED Turns Off Momentarily – Module
acknowledged receiving an RF signal from a remote
RF device.
RF Receiver (RF 3213/E) Wiring
Diagram
EN | 9
2

Hide quick links:

Advertisement

Table of Contents