ICP-VR8488 | Quick Reference Guide | 9.0

Outputs

Location
436 to 465
Output 1 (Default = Horn speaker)
Event Code
Event Code
Time Base
Time Base Multiplier
Time Base Multiplier
Output 2 (Default = Fire alarm with verification)
Event Code
Event Code
Time Base
Time Base Multiplier
Time Base Multiplier
Strobe Output
(Default = Strobe – reset after 8 hours)
Event Code
Event Code
Time Base
Time Base Multiplier
Time Base Multiplier
Relay Output (Default = Sirens running)
Event Code
Event Code
Time Base
Time Base Multiplier
Time Base Multiplier
Codepad Buzzer
(Default = Entry/exit warning plus day alarm)
Event Code
Event Code
Time Base
Time Base Multiplier
Time Base Multiplier
Bosch Security Systems, Inc. | 12/08 | F01U089640-01
Programming Guide
Location
Default
436
1
437
14
Polarity
438
0
439
0
440
0
441
0
442
2
443
7
Polarity
444
10
445
2
446
1
447
5
448
2
449
0
450
Polarity
6
451
4
452
0
453
8
454
1
15
455
Polarity
456
1
457
0
458
0
459
0
460
0
461
13
Polarity
462
2
463
1
464
0
465
1
Event Codes
Event
Description
Code
0
0
EDMSAT – satellite siren (Output 1 only)
0
1
System armed
0
2
System disarmed
0
3
Armed in STAY Mode
0
4
Armed in AWAY Mode
0
5
Pre-arming alert
0
6
Exit warning (all zones sealed) and entry
warning
0
7
Exit warning
0
8
Exit warning finished
0
9
Kiss-off after end of exit time
0
10
Reserved
0
11
Entry warning
0
12
Entry warning and day alarm resetting
0
13
Exit warning and entry warning and day alarm
resetting
0
14
Day alarm resetting
0
15
Day alarm latching
1
0
Day alarm enabled
1
1
Telephone line fail
1
2
Kiss-off received
1
3
AUX Power Supply fail
1
4
AC fail
1
5
Low battery
1
6
Horn speaker fail
1
7
Sensor watch alarm
1
8
Codepad medical alarm
1
9
Codepad fire alarm
1
10
Codepad panic alarm
1
11
Codepad duress alarm
1
12
Access denied (code retries)
1
13
Reserved
1
14
Horn speaker (Output 1 only)
1
15
Sirens running
2
0
Strobe
2
1
Silent alarm
2
2
Alarm in STAY Mode
2
3
Alarm in AWAY Mode
2
4
System fault
2
5
Fire alarm (resetting)
2
6
Fire alarm (latching)
2
7
Fire alarm (verification)
2
8
Remote Control 1
2
9
Remote Control 2
2
10
Remote Control 3
2
11
Radio Control Output 1
2
12
Radio Control Output 2
2
13
Radio Control Output 1 – not in AWAY Mode
2
14
Radio Control Output 2 – not in AWAY Mode
2
15
Communications fail after three attempts
3
0
Communications fail
3
1
Dialer disabled
3
2
Dialer active (on-line)
3
3
Ring detect
EN | 23