ICP-VR8488 | User's Guide | 1.0
1.0 Getting to Know Your
ICP-VR8488
Your ICP-VR8488 Intruder Alarm System is made
up of a control panel and numerous detection
devices such as magnetic/motion sensors and
smoke sensors. You can operate the ICP-VR8488
using either the codepad or RF keyfobs. Your
security company will examine your premises and
divide it up into sections called zones.
If a detection device detects intrusion or smoke,
the status of the device changes from normal to
faulted. If a detection device becomes faulted
when the ICP-VR8488 is armed (AWAY Mode or
STAY Mode), the ICP-VR8488 sounds an alarm
and sends an alarm report by telephone to your
security company. Your security company takes
the appropriate action.
1.1

Zone Types

During installation, your security company might
configure zones on your ICP-VR8488 differently.
These different zones are described in Table 1 on
page 4.
Table 1:
Zone Types
Type
Description
Burglary
A burglary zone is programmed to sound an
alarm only when a fault is detected and the
ICP-VR8488 is armed (AWAY Mode or
STAY Mode). When the ICP-VR8488 is
disarmed, burglary zones do not sound an
alarm if faulted.
24-Hour
A 24-hour zone is programmed to sound an
alarm when a fault is detected (by a tamper
switch, for example) regardless of whether
the ICP-VR8488 is armed.
Fire
A fire zone is programmed to sound an
alarm when a fault is detected (by a smoke
sensor, for example) regardless of whether
the ICP-VR8488 is armed.
Bosch Security Systems, Inc. | 12/08 | F01U089638-01

Getting to Know Your ICP-VR8488

1.2
Figure 1:
1 – Zone Indicators
2 – Service indicator
3 – Power indicator
4 – STAY indicator
5 – AWAY indicator
1.2.1
If the AC MAINS supply fails, both the Power and
Service indicators flash. The keypad beeps once
every minute to warn you that the AC power
supply failed. Press the [#] key once to
acknowledge the AC fail condition and stop the
codepad beeping. When power is restored, the
indicator lights steadily again.
Table 2:
Indicator
AWAY
STAY
Power
Service
Zone
Indicators

ICP-VR8488 Indicators

Keypad Display

AC MAINS Supply Failure

Keypad Indicator States
Description
On – the ICP-VR8488 is armed in AWAY
Mode.
Off– the ICP-VR8488 is not armed in
AWAY Mode.
On – the ICP-VR8488 is armed in STAY
Mode.
Off– the ICP-VR8488 is not armed in STAY
Mode.
On – AC MAINS supply is normal.
Flashing (with Service indicator) – AC
MAINS supply failure.
On– a trouble condition exists. Contact your
security company.
Flashing (with Power indicator) – AC
MAINS supply failure.
On – the zone is faulted.
Off – normal condition.
Flashing – the zone is in alarm.
The OFF indicator lights when the
system is disarmed and flashes when a
zone becomes unsealed when
disarmed. The indicator stops flashing
when all zones are sealed.
The ON indicator lights when the
system is armed and flashes when an
alarm occurs. The indicator resets after
a valid User Code is entered.