Standards - Cannon FITZIB-SDSEB-NG User Instructions

Fitzroy inbuilt
Table of Contents

Advertisement

Do not modify this appliance.
8.
If removed, the glass window must be put back onto the unit prior to
operating the heater.
9. Installation and repairs should be performed by a licensed service
person only, refer to back of brochure for service number.
10. For installation into a non-combustible fireplace, i.e.: masonry or brick
or into a mock fireplace, i.e. timber or plasterboard, the chimney and
base should be of sound construction and be free from cracks and
holes (to ensure that sufficient flue draught can be generated).
Note: when installing into a mock fireplace a mock fireplace
installation kit must be used.
11. The heater must be properly installed in a working chimney or con-
nected to a venting system. Operation of this heater, when not con-
nected into a working chimney or a properly installed and maintained
venting system can result in carbon monoxide (CO) poisoning and
possible death.
12. Testing the effectiveness of the flue.
Before testing the flue confirm air vents are unobstructed. If an exhaust
fan or other heating appliances are present switch them on. This is to
test that there is no interaction between the Cannon heater and other
appliances.
Refer AS5601.
For 'air movement not to affect appliance' see clause 5.3.1.
For 'air supply to appliance' see clause 5.4.1.
For 'ventilation requirements' see clause 5.4.3.
13. The appliance should be inspected prior to use, with regular inspec-
tions (annually) to be made by a licensed service person. It is impor-
tant that circulating air passageways of the appliance be kept clean,
dirt and lint free, for a safe and efficient operation of the heater.
14. On first lighting your heater a smell may occur due to its new condi-
tion. This is quite normal and will disappear after a few hours use at
the maximum control position.
Important:
When this heater is operating the mesh guard/glass front is hot.
The mesh guard, or glass front, fitted to the heater conforms to
Australian Standards requirements.
The guard is fitted to this appliance to reduce the risk of fire or
injury from burns and no part of it should be permanently re-
moved.
For protection of young children or the infirm, a secondary guard
is required.

Standards

This appliance meets the following standards:
Standards Australia: AS/NZS 3100
AS 5601
AS 4553:2008
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fitzib-sdseb-lp