In a study in rats of chronic inhalation exposure to a typical toner, a mild to moderate
degree of lung fi brosis was observed in 92% of the rats in the high concentration (16
mg/m3) exposure group. A minimal to mild degree of lung fi brosis was observed in
22% of the rats in the middle (4 mg/m3) exposure group. No pulmonary change was
reported in the lowest (1 mg/m3) exposure group, the most relevant level to potential
human exposures.
Exposure Limits (ACGIH TLV):
Inhalable Particulate: 10 mg/m3
Respirable Particulate: 3 mg/m3
Irritancy: Not available.
Sensitivity: Not available.
Carcinogenicity
IARC: No components are listed.
NTP: No components are listed.
OSHA: No components are listed.
Reproductive Toxicity: Not available.
Teratogenicity: Not available.
Mutagenicity: Not available.
Name of Toxicoligically Synergistic Products: Not available.

Reactivity Data

Stability: Stable in general.
Materials to Avoid: None.
Polymerization: Will not occur.
Hazardous Decomposition or Byproducts: Combustion products include carbon
monoxide and carbon dioxide.
Incompatibility: Avoid exposure to strong oxidizers.

Preventive Measures

Personal Protective Equipment

Respiratory Protection: Not normally required. For large spills, use dust respirator
mask during cleanup.
Protective Gloves and/or Eye Protection: Not normally required. For large spills,
use leather gloves and safety goggles during cleanup.

Engineering Controls

Ventilation: Outside of normal ventilation, not normally required.
Other Protective Equipment and/or Hygienic Practices: None.