Materials to Avoid: None.
Polymerization: Will not occur.
Hazardous Decomposition or Byproducts: Combustion products include carbon
monoxide and carbon dioxide.
Incompatibility: Avoid exposure to strong oxidizers.

Preventive Measures

Personal Protective Equipment

Respiratory Protection: Not normally required. For large spills, use dust respirator
mask during cleanup.
Protective Gloves and/or Eye Protection: Not normally required. For large spills,
use leather gloves and safety goggles during cleanup.

Engineering Controls

Ventilation: Outside of normal ventilation, not normally required.
Other Protective Equipment and/or Hygienic Practices: None.

Spill Cleanup

Small Spills
1.
Remove sources of ignition.
2.
Carefully clean up the spill with a wet cloth, avoiding inhalation of fi ne dust.
Large Spills
1.
Remove sources of ignition and keep unnecessary and unprotected personnel
away from area.
2.
Wear protective gear: dust respirator mask, leather gloves, safety goggles.
3.
Vacuum or sweep the material into a bag or other sealed container, then wipe
up remainder with a wet cloth.

Waste Disposal

Prevent release of material into natural waters and sewers.