Server System Features - MAXDATA PLATINUM 500 I System Manual

Hide thumbs Also See for PLATINUM 500 I:
Table of Contents

Advertisement

2 Server System Features

This chapter briefly describes the main features of the server system. This chapter provides a list of
server system features and diagrams showing the location of important components and connections
of the server system.
Table  summarizes the features of the server system.
Table 2. Server System Features
Merkmal
Server board
Processors
System memory
Chipset
Peripheral
interfaces
Graphics
LAN
Expansion
capabilities
HDD Cages
Power supply
Fan
Server
management
MAXDATA Server PLATINUM 500 I M7
Beschreibung
Intel
S5500BC
®
Up to two Intel
Xeon
5500 processors with a thermal design power (TDP) of up
®
®
to 95 W
• 8 DIMM slots, 4 per processor, distributed over two memory channels
• Up to 32 GB system memory
• 800/1066/1333 MT/s ECC registered (RDIMM) or unbuffered (UDIMM) DDR3
memory
• No mixing of RDIMMs and UDIMMs
• Intel
5500 Chipset IOH
®
• Intel
82801Jx I/O Controller Hub (ICH10R)
®
External connections:
• One DB-15 graphics port
• One serial DB-9 port
• Two RJ45 network ports for 10/100/1000 Mbps
• Four USB 2.0 ports (back panel)
• Two USB 2.0 ports (front)
Internal connections:
• One USB connector for two USB 2.0 ports
• One DH10 connector for serial A port
• Six SATA-II ports with integrated RAID 0/1/10 support
• One port for an optional remote management module 3
On-board controller ServerEngines LLC Pilot II with integrated 2D video controller,
64 MB DDR2 memory, 8 MB of which is graphics memory
Two RJ45 ports for 10/100/1000 Mbps Ethernet LAN:
• One Intel
82574L GbE controller
®
• One Intel
82567 GbE controller
®
• Two PCI-E 2.0 x8 expansion slots
• One PCI-E 2.0 x8 expansion slot with x4 connection
• One PCI-E 1.1 x4 expansion slot
• One 5 V 32-bit / 33 MHz PCI expansion slot
• Up to 2 HDD cages with max. ten 2.5" or eight 3.5" HDD
a) Drive cage for fixed 3.5" hard drives (max. 1 per system, 2 HDD supported)
b) SAS / SATA cage with four 3.5" hot-swap drive bays
c) SAS / SATA cage with six 2.5" hot-swap drive bays, expander backplane with
two 7-pin SATA connectors
• HDD cages can be combined
• SAS support through optional SAS controller
Simple or redundant 600 W / 650 W power supply
• Three 120 mm chassis fan
• One non-redundant fan in every power supply
• An integrated IPMI 2.0-compliant baseboard management controller
• Support for remote management module 3 ("KVM over IP")
• Support for system management software
• Light Guided Diagnostics on replaceable units (FRUs)