Close And Lock Load Plate; Installing The Heat Sink - MAXDATA PLATINUM 500 I System Manual

Hide thumbs Also See for PLATINUM 500 I:
Table of Contents

Advertisement

1. Replace the load plate.
14. Close the socket lever. Push down on the lever and, while holding it down, push it towards the
centre of the processor until it clicks into place under the hook on the processor socket.
15. Attach the heat sink (see next page).
Installing the Heat Sink(s)
The heat sink has Thermal Interface Material (TIM) located on the bottom of it. Use caution when
you unpack the heat sink so you do not damage the TIM.
1. Set the heat sink over the processor, lining up the four captive screws with the four posts
surrounding the processor.
. Loosely screw in the captive screws on the heat sink corners in a diagonal manner.
Do no fully tighten one screw before tightening another.
. Gradually and equally tighten each captive screw until each is firmly tightened.
4. Reinstall and reconnect any parts you removed or disconnected to reach the processor sockets.
5. Replace the server's cover and reconnect the AC power cord.
MAXDATA Server PLATINUM 500 I M7
MAXDATA Server PLATINUM 500 I M7
Figure 18. Close and Lock Load Plate
3
2
4
Figure 19. Installing the Heat Sink
1
1
1