Maytag MAH22PDAXW1 Installation Instructions Manual page 7

Commercial automatic washer

Advertisement

Available languages

Available languages

The washer
can be installed
using the standpipe
drain system (floor or wall),
the laundry
tub
drain
system, or the floor drain
system. Select the drain hose installation
method
you need.
See "Tools and Parts."
Standpipe
drain
system
- wall
or floor
(views
A & B)
The standpipe
drain
requires
a minimum
diameter
standpipe
of 2" (5 cm). The minimum
carry-away
capacity
can be no less than 1 7 gal. (64 I_) per minute.
The top of the standpipe
must be at [east 30" (76.2 cm) high and no higher
than 96" (2.4 m)
from the bottom
of the washer.
T
30"rnin.
(76.2 ira)
B
Laundry
tub drain
system
(view
C)
The laundry
tub needs a minimum
20 gal. (76 I.) capacity.
The top of the laundry
tub must be
at [east 30" (76.2 cm) above the floor.
Floor
drain
system
(view
D)
The floor
drain system requires
a siphon
break that may be purchased
separately.
See "Tools
and Parts."
The siphon
break
must be a minimum
of 28" (71 cm) from the bottom
of the washer.
Additional
hoses might be needed.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet,
Do not remove ground prong,
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A 120 volt, 60 Hz., AC only, 15- or 20-amp,
fused electrical
supply
is required.
A time-
delay fuse or circuit
breaker
is recommended.
It is recommended
that a separate circuit
serving only this appliance
be provided.
This washer
is equipped
with
a power supply
cord having
a 3 prong grounding
plug.
To minimize
possible
shock hazard,
the cord must be plugged
into a mating,
3 prong,
grounding-type
outlet,
grounded
in accordance
with
local codes and ordinances.
If a
mating outlet
is not available,
it is the personal
responsibility
and obligation
of the
customer
to have the properly
grounded
outlet
installed
by a qualified
electrician.
If codes permit
and a separate ground
wire is used, it is recommended
that a qualified
electrician
determine
that the ground
path is adequate.
C
D