Installation hole
Dowel
Installation hole
Dowel
OK (LOCKED)
NG (UNLOCKED)
Changing Cartridges
16. Install the fusing unit by
inserting the dowel of the
mount into the fusing unit's
installation hole.
17. Secure the fusing unit with
the installation screws.
18. Turn the misfeed clearing
dial of the fusing unit coun-
terclockwise and make sure
that the white gear shown
rotates smoothly.
19. Holding the lock release
lever, insert the fusing unit
until it clicks into place.
20. Make sure that the button of
the fusing unit lock
release lever is pushed up as
shown.