IN STALLATION REQUIREMENTS
Island trim and attachment
screws (3).
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Tools needed
Tape measure
1¾6"combination
wrench
Flat-blade screwdriver
Marker or pencil
Phillips screwdriver
Masking tape
Level
Pipe-joint compound
resistant to LP gas
Hand or electric drill
Channel lock pliers
Noncorrosive leak-detection
solution
Pipe wrench
Stud finder
NOTE: The island trim included with the range may be used if
installed with 1" (2.5 cm) clearance on the 30" (76.2 cm)
model or 5" (12.7 cm) clearance on the 36" (91.4 cm) model
from a combustible
rear wall or with 0" (0 cm) clearance from
a noncombustible
rear wall,
LP conversion kit.
NOTE: The cooktop is manufactured
for use with Natural gas.
To convert to LP gas, see the gas conversion instructions
provided in the literature package.
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See "Electrical Requirements"
and
"Gas Supply Requirements"
sections.
All electrical connections should be made by a licensed, qualified
electrical installer.
Parts needed
A UL listed or CSA approved conduit connector
ULlisted
wire nuts
Parts supplied
Check that all parts are included.
Anti-tip bracket kit
1"
A(2.5 cm)'--1 Ii_
I_¢/-"
I
(4.4
cl__
)
C
A. Anti-tip bracket - 1" (2.5 cm)
B. Anti-tip bracket - 13/4"(4.4 cm)
C. #!0 x 2" Phillips head screws (2)
NOTE: Brackets must be securely attached to wall stud.
Thickness of finished wall may require longer screws to anchor
bracket to wall. Longer screws are available from your local
hardware store. See "Install Anti-Tip Bracket" section.
Backguard and attachment
screws (7).
NOTE: The backguard included with the range is required if
installed with less than 1" (2,5 cm) clearance from a
combustible
rear wall.
IMPORTANT." Observe all governingcodes and ordinances. Do
not obstruct flow of combustion
and ventilation air.
It is the installer's responsibility
to comply with installation
clearances specified on the model/serial rating plate. The
model/serial
rating plate is located on the right vertical
surface of the oven door frame.
It is recommended
that a 600 CFM or larger range hood be
installed above the range.
Recessed installations must provide complete enclosure of
the sides and rear of the range.
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
All openings in the wall or floor where range is to be installed
must be sealed.
Do not seal the range to the side cabinets.
Cabinet opening dimensions that are shown must be used.
Given dimensions
are minimum clearances.
The wall anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see "Install Anti-Tip
Bracket" section.