Gas Supply Requirements - KitchenAid YKDRP707RS00 Installation Instructions Manual

30" (76.2 cm) and 36" (91.4 cm) classic commercial style dual fuel convection range with steam-assist
Table of Contents

Advertisement

Available languages

Available languages

Electrical Shock Hazard
Electrically ground
range.
Failure to do so can result in death, fire, or
electrical
shock.
codes permit and a separate ground wire is used, it is
recommended
that a qualified electrical installer determine that
the ground path and wire gauge are in accordance
with local
codes.
Be sure that the electrical connection and wire size are adequate
and in conformance
with the CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA.
Do not ground to a gas pipe.
Check with a qualified electrical installer if you are not sure
the range is properly grounded.
Do not have a fuse in the neutral or ground circuit.
When a 4-wire, single phase 208/240 volt, 60 Hz., AC only
electrical supply is available, a 30-amp minimum circuit
protection is required, fused on both sides of the line.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range's final location.
Do not use an extension cord.
I_
_,
I:_ ......
.......... ,_
, ....
Explosion Hazard
Use a new CSA international
approved
gas supply
line.
Install a shut-off
valve.
Securely tighten
all gas connections.
If connected
to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified
person include:
licensed
heating personnel,
authorized
gas company personnel, and
authorized
service personnel.
Failure to do so can result in death, explosion, or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances.
In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest
edition.
IMPORTANT: Range cooktop must be connected to a regulated
gas supply.
Type of Gas
Natural Gas:
This range is design-certified
by CSA International for use with
Natural gas or, after proper conversion, for use with LP gas.
This range is factory set for use with Natural gas. The model/
serial rating plate located on the right vertical surface of the
oven door frame has information on the types of gas that can
be used. If the types of gas listed do not include the type of
gas available, check with the local gas supplier.
LP Gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier. To convert to LP
gas, use the LP gas conversion kit provided with your range. The
parts for this kit are in the literature package supplied with the
range.