Appendix

Appendix 1: Reference Sheet of Celsius and Fahrenheit

Conversion formula for Fahrenheit degree and Celsius degree: Tf=Tcx1.8+32
Set temperature
Fahrenheit display
Fahrenheit
temperature(℉)
(℉)
61
60.8
62/63
62.6
64/65
64.4
66/67
66.2
68
68
Ambient temperature
Fahrenheit display
Fahrenheit
temperature(℉)
( ℉ )
32/33
32
34/35
33.8
36
35.6
37/38
37.4
39/40
39.2
41/42
41
43/44
42.8
45
44.6
46/47
46.4
48/49
48.2
50/51
50
52/53
51.8
54
53.6

Appendix 2: Configuration of Connection Pipe

1.Standard length of connection pipe(More details please refer to the specifications.)
2.Min length of connection pipeFor the unit with standard connection pipe of 5m, there is no limitation for themin length of
connection pipe. For the unit with standard connection pipe of 7.5m and 8m, the min length of connection pipe is 3m.
3.Max. length of connection pipe and max. high difference.(More details please refer to the specifications.)
4.The additional refrigerant oil and refrigerant charging required after prolonging connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for each
additional 5m of connection pipe.
● The calculation method of additional refrigerant charging amount (on the basis of liquid pipe):
● Basing on the length of standard pipe, add refrigerant according to the requirement as shown in the table. The additional refrigerant
charging amount per meter is different according to the diameter of liquid pipe. See the following sheet.
● Additional refrigerant charging amount = prolonged length of liquid pipe X additional refrigerant charging amount per meter
Piping size
Liquid pipe
1/4"
1/4" or 3/8"
1/2"
5/8"
3/4''
7/8''
88
Celsius
Fahrenheit display
temperature(℉)
(℃)
16
69/70
17
71/72
18
73/74
19
75/76
20
77
Celsius
Fahrenheit display
temperature(℉)
(℃)
0
55/56
1
57/58
2
59/60
3
61/62
4
63
5
64/65
6
66/67
7
68/69
8
70/71
9
72
10
73/74
11
75/76
12
77/78
Additional refrigerant charging amount for R22, R407C, R410A and R134a
Gas pipe
3/8" or 1/2"
5/8" or 3/4"
3/4" or 7/8"
1" or 1 1/4"
/
/
Fahrenheit
Celsius
Fahrenheit display
temperature(℉)
(℉)
(℃)
69.8
21
71.6
22
73.4
23
75.2
24
77
25
Fahrenheit
Celsius
Fahrenheit display
temperature(℉)
(℉)
(℃)
55.4
13
57.2
14
59
15
60.8
16
62.6
17
64.4
18
66.2
19
68
20
69.8
21
71.6
22
73.4
23
75.2
24
77
25
Outdoor unit throttle
Cooling only(g/m)
15
15
30
60
250
350
Service Manual
Fahrenheit
(℉)
78/79
78.8
80/81
80.6
82/83
82.4
84/85
84.2
86
86
Fahrenheit
(℉)
79/80
78.8
81
80.6
82/83
82.4
84/85
84.2
86/87
86
88/89
87.8
90
89.6
91/92
91.4
93/94
93.2
95/96
95
97/98
96.8
99
98.6
Cooling and heating(g/m)
20
50
120
120
250
350
Installation and Maintenance
Celsius
(℃)
26
27
28
29
30
Celsius
(℃)
26
27
28
29
30
31
32
33
34
35
36
37