Chapter 7: System Checking; Trouble View; Quick Trouble View - O.Y.L. Technology AX1 LED User Manual

Security & home automation system
Table of Contents

Advertisement

AX1 LED User Manual
7.0

TROUBLE VIEW

System must be in normal or armed mode in order to view trouble. Control panel will
monitor a number of possible trouble conditions. If one of these conditions occurs, the
SERVICE light will turn ON and remain ON until trouble free and/or it receives clearance
instruction from the users. There are only 8 conditions available designated by indication
lights (1 to 8, indication light 9 will remain OFF all the time).

7.1.1 QUICK TROUBLE VIEW

Command
To view the trouble condition:
Press
and hold for 2 sec
To Exit View Trouble mode
Press [#]
Trouble
DC Loss (Low Battery)
Bell Strobe Siren Loss
External
Communication Error
Internal
Communication Error
Short Circuit
Tamper
Phone Line Loss
AC Loss

CHAPTER 7: SYSTEM CHECKING

Information
 The service light will FLASH to indicate that
keypad is under View Trouble Mode.
 Designated zone light is used to reflect the type of
problem. (Refer to table below)
 The service light will be ON if the trouble
conditions still remain.
 The designated zone light will be restored back to
the actual zone‟s status.
Display
Zone 1 LED turn on
Zone 2 LED turn on
Zone 3 LED turn on
Zone 4 LED turn on
Zone 5 LED turn on
Zone 6 LED turn on
Zone 7 LED turn on
Zone 8 LED turn on
Causes
Backup battery in weak or backup battery
is not available.
Either bell, strobe or siren is loss.
Unable to call out either due to no reply
by user during reporting.
LED keypad and IO Expander cannot
communicate with control panel due to
main panel or connection failure.
One or more of the part in AP1, AP2,
AP3, BELL, SL, SIREN port is short
circuit.
Tamper occurred and has not been cleared
by alarm memory clear
No phone line connected to the system
No power supply detected
Rev 1.0