LIGHT INDICATION

No
Description
1
Normal Mode
2
Arming
3
Home Automation
Mode
4
User Programming
Mode
5
AC power failure
6
Trouble occurs
7
View Trouble Mode
8
Zone Status
(Triggered)
(Bypassed)
(Alarmed)
9
Tamper zone triggered
10
Telephone line loss
alarm triggered
11
Walk test
AX1 LED Keypad Display's Reference Table
NOTE:
*
: When AC power ON, LED is ON; When AC power failure, LED is OFF
**
: When armed, LED = ON
When Emergency/Fire/Panic, LED = Flash
When disarmed, LED = OFF
***
: When trouble occurs, LED is ON; when no trouble occurs, LED is OFF
Flash
:
Fast flash
:
KEYPAD NAVIGATION KEY FUNCTION
[COM] Key : Command
[#] Key : Enter
[*] Key : Cancel
Power
*
*
Flash
Flash
OFF
*
*
*
*
*
*
*
*
0.5 second ON, 0.5 second OFF
0.1 second ON, 0.1 second OFF
Armed
Service
OFF
***
ON
***
OFF
Flash
Flash
Flash
**
ON
**
ON
**
Flash
**
***
**
***
**
***
Fast flash
***
Fast flash
Fast flash
Flash
Flash
Rev 1.0
Zones
Pending
Pending
Pending
Pending
Pending
Pending
ON according to the type
of trouble
ON
Flash
Fast flash
All zone‟s LEDs
Fast flash
Pending
Pending
6