7. Make sure the manually configured network settings are correct.

2.4 Replace the hot-swap redundant power supply

The NAS-5400 comes with two power supplies; each has a LED indicator. If the power cord is
connected and the A/C switch is at ON position, but the LED is still off, the power supply is failed.
Please follow the procedures below to replace it.
1. Switch-off the AC switch of the failed power supply. Disconnect its power cord.
2. Unlock the thumbscrew of the failed power supply.
3. Pull out the failed power supply by the handle. Replace a new one and lock the thumbscrew.
4. Connect the AC power cord and switch on the power.

2.5 Turn off the NAS Server

There are two ways to turn off the NAS-5400.
1. When the NAS-5400 is running, you can turn it off by pressing the power control button once.
The NAS-5400 will shutdown automatically after around 20 seconds. Do not press the power
button continuously for over 4 seconds, for this action will turn off the power immediately and
may cause the server non-operational or corrupt the drives.
2. You can turn off (shutdown) the NAS-5400 via Toolkits option of its web management interface.