Air Shutter Adjustment - Travis Industries 33 DVI Owner's Manual

Gas insert
Hide thumbs Also See for 33 DVI:
Table of Contents

Advertisement

24
8.
Check the air shutter following the directions below.

Air Shutter Adjustment

Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be
yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame.
Correct
Flames should be blue at the
base, yellow-orange on the top.
Swing the control cover down to
access the air shutters.
9. Attach the face following the directions included with the face.
NOTE: If using a Rosario or Discovery face you will need to modify the face connector (see page 11
for details).
NOTE: If using the Arched, Artisan, Metropolitan, or Victorian Lace Face you must use the face
mounting brackets included with the heater (see page 11 for details).
10. Adjust the flame to its highest position - the flames should not contact the top of the firebox. Check the flame on low
position. The flames should burn off of each burner hole. If the heater does not work correctly, contact your Travis dealer
for a remedy.
11. Give this manual to the home owner for future reference and fully explain operation of this heater.
© Travis Industries
Finalizing the Installation
Not Enough Air
If the flames are too tall or sooty on the
ends, open the air shutter.
4100322
Too Much Air
If the flames are all blue and
short, close the air shutter.
Front Burner Air Shutter Control
Rear Burner Air Shutter Control
(GOLD)
Left = Less Air
Right = More Air
(RED)
Right = Less Air
Left = More Air
100-01237_000