Travis Industries 35 CB Australian Owner's Manual

Direct vent fireplace
Table of Contents

Advertisement

WARNING:
If the information in these instructions are not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
-
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
-
Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
This appliance shall be installed in accordance with the manufacturer's installation
instructions, local gas fitting regulations, municipal building codes, electrical wiring regulations,
AS5601 - 2000 (AG601) Gas Installations and any other relevant statutory regulations.
This appliance is only for use with the type(s) of gas indicated on the rating plate. A conversion
kit is supplied with the appliance.
Installer: After installation give this manual to the home-
owner and explain operation of this fireplace.
 Copyright 2002, T.I.
$10.00
(CB) Owner's Manual
Part # 93508134
35 Custom Builder
Tested and Listed by
Omni-Test Laboratories, Inc.
Beaverton, Oregon - Report # 028-5-35-5
ANSI Z21.88, CSA 2.33 M9 8, CAN/CGA 2.17-M91
Direct Vent Fireplace
• Natural Gas or Propane
• Standard Residential
• Mobile Home Approved
Dragon Wholesaling
Unit 2, 23 Victoria Ave - Castle Hill, NSW, 2154
Tel: (02) 9894-7950 - Fax: (02) 9894-7265

Advertisement

Table of Contents
loading

Summary of Contents for Travis Industries 35 CB Australian

  • Page 1 35 Custom Builder (CB) Owner’s Manual Tested and Listed by Omni-Test Laboratories, Inc. Beaverton, Oregon - Report # 028-5-35-5 ANSI Z21.88, CSA 2.33 M9 8, CAN/CGA 2.17-M91 • Direct Vent Fireplace • Natural Gas or Propane • Standard Residential • Mobile Home Approved WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 3: Important Information

    This serial number will be needed in case you require service of any type. To receive full warranty coverage, you will need to show evidence of Model: 35 CB Australian the date you purchased your fireplace. Do not mail your Bill of Serial Number: Sale to us.
  • Page 4: Safety Precautions

    Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 5 Always follow the instructions in this manual. • If the fiber logs become damaged, replace with Travis Industries log set. • Do not touch the hot • Keep all furniture or other surfaces of the fireplace. combustible items at least Educate all children of the 36"...
  • Page 6: Table Of Contents

    Hearth Requirements ........9 How this Fireplace Works.......34 Facing Requirements ........10 What Turns the Main Burners On and Off..34 Facing Detail for 35 CB Faces ......11 What Prevents Gas Buildup.......34 Facing Detail for 36 DV Faces ......12 Wiring Diagram ..........35 Face Installation - 35 CB Face ......13 Replacement Parts List .........35...
  • Page 7: Features & Specifications

    (740 mm) 31-1/2" (800 mm) 34-1/4"* (619 mm)* 40-3/8" 16-7/8"* (1026 mm) (429 mm)* * Includes the 1/2" (13 mm) 1/2" (13 mm) stand-offs Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 8: Installation

    This appliance must be installed in accordance with all local codes, if any; if not, in U.S.A. follow ANSI Z223.1 and NFPA 54(88), in Canada follow B-149. The 35 CB is designed to operate on natural gas or propane (LP). All exhaust gases must be vented outside the structure of the living-area.
  • Page 9: Fireplace Placement Requirements

    (e.g. drapes, doors) • Fireplace must be placed so the vents below and above the glass do not become blocked Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 10: Corner Installations

    Raised fireplace with Raised fireplace raised hearth. Raised Platform Raised Hearth Hearth Raised Nail the nail down plates to the floor Platform (or raised platform) Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 11: Hearth Requirements

    The fireplace must be raised to accommodate any flooring thicker than 3/4" (19 mm). Maximum 3/4” (19 mm) Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 12: Facing Requirements

    Mask off the front of the fireplace to keep drywall dust from entering the fireplace. These particles, when heated, may cause odors or cause other problems. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 13: Facing Detail For 35 Cb Faces

    Installation (for qualified installers only) Facing Detail for 35 CB Face Flush Facing - Top View Tile Facing - Top View Recessed Tile Facing - Top View Flange on Framing Framing Framing Drywall Flange on Flange on Standoff Drywall Drywall 1/2"...
  • Page 14: Facing Detail For 36 Dv Faces

    We recommend placing a 7/8” (22 mm) (13 mm) thick hearth in front of the face to conceal this opening. 1/2" (13 mm) Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 15: Face Installation - 35 Cb Face

    Installation (for qualified installers only) Face Installation - 35 CB Face Hang the 35 CB Face on the screws and bushings at the top inside of the drywall standoff. Phillips Screwdriver Secure the face with these two screws (the screws are attached to the fireplace).
  • Page 16: Face Installation & Sizing - 36 Dv Face

    Access Door 36-1/4” (921 mm) 38” (965 mm) * Artisan faces may vary slightly in size due to the forging process. Access Door Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 17: Mantel Requirements

    Max. 12” (305 mm) Combustible or (from faceplate) Non-Combustible Mantel Min. 42” (1067 mm) (from base of fireplace) Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 18: Vent Requirements

    48" (1219 mm) Pipe Length, Black (interior) Ceiling Fire-stop High Wind Vertical 911B 11" (279 mm) to 14 5/8" (356 mm) Wall Strap Termination Adjustable, Black (interior) Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 19: Vent Installation

    Horizontal sections require a 1/4" (6 mm) rise every 12" (305 mm) of travel • Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape) Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 20: Approved Vent Configurations

    Vent sections overlap each other by 1-1/2" (38 mm) Vent 30-7/8" Height Vent Length (784 mm) 1-1/2" 3' (915 mm), (38 mm) 4' (1219 mm), etc. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 21: Vertical Term. 0, 2, Or 4 45° Offsets

    Position # 4 Intake Restrictor Setting: Position # 6 Vent Restrictor Setting: Position # 1 (fully Vent Restrictor Setting: Position # 7 open) Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 22: Horizontal Term. With One Elbow

    Position # 4 Intake Restrictor Setting: Position # 6) Vent Restrictor Setting: Position # 1 (fully open) Vent Restrictor Setting: Position # 9 Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 23: Vertical Term. With Two Elbows

    Intake Restrictor Setting: Position # 4 Vent Restrictor Setting: Position # 1 Intake Restrictor Setting: Position # 4 Vent Restrictor Setting: Position # 5 Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 24: Vent Termination Requirements

    Vent termination must not be located where it will become plugged by snow or other material • These clearances meet AS5601-2000 (AG601) Gas Installations standards. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 25: Gas Line Requirements

    The socket outlet for this heater shall be installed near the heater and shall be easily accessible for service or operation. For remote switching of the fan, consult a suitably qualified electrician. Travis Industries 9 3 5 0 8 1 3 4...
  • Page 26: Finalizing The Installation

    Swing the glass frame outwards then lift the it firebox. Secure the glass frame with the latches. up and off the tabs at the top of the firebox. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 27: Log Installation

    Place the embers on this ledge at the front of the firebox . Do not place the embers over the burner holes. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 28: Leak Test

    If the flames are all blue and base, yellow-orange on the top. or sooty on the ends, contact your local short, contact your local service service provider. provider. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 29: Check Flame

    The flames should burn off of each burner hole. If the heater does not work correctly, contact your dealer for a remedy. Give this manual to the home owner and fully explain the operation of this heater. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 30: Operation

    If using a remote control or thermostat, the On/Off Switch must be left "ON". Turning the On/Off Switch "OFF" will keep the fireplace off always. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 31: Starting The Pilot

    Replace the glass. Turn the gas control knob counter-clockwise to "ON". The pilot is now lit and the fireplace can be turned on and off. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 32: Starting The Fireplace For The First Time

    Index Mark Flame Height Adjustment Knob Turn counter-clockwise to adjust the flame higher, clockwise to lower. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 33: Normal Operating Sounds

    This is the valve opening up sound as it turns the and shutting down. blower on and off. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 34: Maintenance

    Start the pilot and turn on the main burner. The flames should be orange/yellow and not touch the top of the firebox. If the pilot or main burners do not burn correctly, contact your dealer for service. Inspect the glass. If damage is found, replace the glass (with frame) with Travis Industries glass assembly (glass installation is on page 24).
  • Page 35: Troubleshooting Table

    See "Log Set Installation & Removal" Thin Layer of Soot Covers the Glass Improper air shutter adjustment Adjust Air Shutter - contact your dealer Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 36: How This Fireplace Works

    If the pilot flame tested to be extremely resistant to goes out, the gas valve automatically breakage from temperature changes. shuts off all gas. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 37: Wiring Diagram

    Optional Regulator Blue Solenoid Black Blue Replacement Parts List Caution: Use only Travis Industries replacement parts. Do not use substitute materials. 93006512 Air Shutter, Assembly 98900747 On/Off Switch, Small, 1996 & Later Gas Models 93006912 Air Shutter Control Arm 93006855...
  • Page 38: Safety (Listing) Label

    Use Simpson DURA-VENT direct vent system (Model GS) to vent this appliance to the exterior (direct discharge only without duct connection). exclusively for Dragon Wholesaling Pty Ltd Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 39: Warranty

    Wholesaling 2,23 Victoria Ave - Castle Hill, NSW, 2154. Dragon Wholesaling warrants this gas appliance (appliance is defined as the equipment manufactured by Travis Industries, Inc.) to be defect-free in material and workmanship to the original purchaser from the date of purchase as follows: Years 1 &...
  • Page 40: Optional Equipment

    This tube on the burner Remove the burner pan. inserts into this tube on the mixing tube. 1/4" Nutdriver Remove the burner pan base. 1/4" Nutdriver Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 41 Screw the LP orifice in 5/16” so the orifice shoulder The NG orifice protrudes 5/16” has “43” stamped on it (2.25 mm) (indicating full insertion). Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 42 NOTE: this illustration shows the gas control valve Remove the regulator with the inlet to the left. On the FPX 35 CB the valve from the front of the will be rotated 180°. gas control valve.
  • Page 43 Place the side firebacks in place. Secure with a fireback clip and screw. Repeat for the opposite side. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 44: Thermostat

    Expose 1/2” (10 mm) of wire and attach to these two posts. Re-attach the cover removed in step “a”. Standard Screwdriver Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 45: Remote Control Thermostat

    Face Mounting Kit (for mounting 36 DV Faces) (part # 98500536) See the instructions on page 14. Travis Industries 9 3 5 0 8 1 3 4 4 0 3 0 6 2 4...
  • Page 46: Index

    Dura-Vent (part numbers)........16 Piping Installation (see Gas Line Install)....23 Elbows.............18 Raised Fireplaces ..........8 Face Dimensions (36 DV)........14 Remote Control Installation........43 Face Installation (35 CB)........13 Remote Control Operation ........43 Face Installation (36 DV)........14 Restrictor Position ..........18 Facing Requirements........10 Safety Label.............36 Finalizing the Installation........24 Safety Precautions ...........2...

This manual is also suitable for:

35 custom builder

Table of Contents