Lamp
Please turn off the projector and unplug the AC power cord. And then, let the projector
cool down at least 60 minutes.
Replacing New Lamp
LC-XNB4000N Part Number:23040043
LC-XNB3500N Part Number:23040044
LC-WNB3000N Part Number:23040044
1. Remove the lamp door.
2. Loosen 2 screws of the lamp holder. Hold the handle on the top of the lamp, pull out
the lamp straight off the projector.
3. Insert new lamp, lock the lamp door firmly with 2 screws.
4. Put the lamp door on.
5. Please reset the lamp timer after replacing lamp. (P.71)