the battery while the generator engine is running. Disconnect the cables from
the battery while the generator is in storage.
4.4 - Starting the Generator Set
GROUND TERMINAL
Before using generator, a ground wire must be connected to the ground terminal.
The Ground terminal is located on the Front Panel. Before using the ground terminal
consult a qualified electrician.
Ground Terminal Symbol:
The HCP9000 generator can be started using three methods.
• Recoil Start Method,
• Electronic Start Method,
• Remote Start Method
IF USING PROPANE FUEL SOURCE
1. Ensure that there is no gasoline in the engine. If gasoline was used in
the most recent operation, start the generator with gasoline source -
once running, close the fuel valve lever and allow engine to run until all
remaining gasoline has been used. After the engine stops, continue to
step 2.
2. Ensure that the fuel valve lever is in the CLOSE position.
3. After tank is properly connected, turn on propane fuel source. Refer to
section 4.2 for LPG connection procedure.
4. Push LPG Converter button 2-3 times to bleed air in the LPG path
5. Push the choke lever in OPEN position.
6. Continue to desired start-up method.